OPERATION INSTRUCTIONS
1. Turn on the filter pump.
2. Start up the unit:
Plug the power cord into the
electrical outlet and test the
GFCI/RCD (circuit breaker).
Switch on the unit. Flashing code
“00” appears on the electronic control
station’s LED, indicating that the unit is ready to be programmed.
3. Set operating hours for Saltwater system:
With code “00” flashing, press button to
set the desired operating hours. See the
“Operating Time Table” for the required
operating hours related to each pool size.
Pressing will increase the time from 01
to 12 hours maximum. If you have selected
too many hours keep pressing to repeat
the cycle. The built-in timer will now activate
your Saltwater System, at the same time
each day, for the number of hours you have set.
NOTE: The Saltwater System will not operate if the filter pump is not operating. Make
sure to program your filter pump (or start it manually) for operation beginning 5 minutes
before the saltwater system and finishing 15 minutes after the saltwater system.
4. Lock keypad controls:
With the desired hour value showing, press button until
you hear a “beep”. A green “WORKING” indicator on the
control panel will light up within a few seconds to indicate that
the saltwater system has started chlorine production. Locking
the control buttons into this setting prevents unauthorized
changing of the operating cycle.
NOTE: If you forget to lock the keypad controls, the system
will automatically lock it and start working 1 minute later.
5. Readjust operating time if necessary:
The operating hours can be re-adjusted if necessary.
Press button until you hear a “beep” to unlock the
keypad and the current programmed time will flash.
Repeat steps 3 to 4.
6 . Test the copper concentration in the pool water.
The Saltwater System recommends a copper level
of 0.1 to 0.2 ppm.
This is easily tested by the copper
ion test strips provided. If the test result is 0.1~0.2ppm,
go directly to step 8.
(1 to 12 hours max per cycle)
OK
0
Copper (ppm)
0.1
0.2
0.5
0.9
1.3