68



B.6 Pull-up Resistor Dip Switch Settings


These dipswitches are located inside the back cover of the IG5 ignition computer. The
dipswitches are arranged to allow pull-up resistors to be switched in to appropriate outputs as
required.

Some factory ignition systems have built in pull-up resistors and will not require the dip
switch pull-ups to be set.

The dip switch pull-ups will be required if using factory ignition modules in conjunction with
the constant charge and falling edge spark.

The following is a list of the switch number versus output :-

1

Aux Out2

2

Aux Out1

3

Ign. Out

4

Aux Out4

5

Aux Out3

6

Tacho

Pull-up

7

Bypass

8

Not Used



To turn the pull-up resistor on for a particular output, push the switch into the down position











This is a view as seen from the back of the IG5 ignition computer.

Note: Due to the enormous variety of ignition modules currently available, It

may necessary to have additional pull-up resistors fitted. Consultation with

Haltech may be required.

1 2 3 4 5 6 7 8

ON