Chapter 2, Specifications, Basic specifications – Hardy HI 6300 Series User Manual
Page 13: General, Number of channels, Update rate, Resolution, Waversaver, Averages, Input

Specifications
5
•
•
•
•
•
•
Chapter 2
• • • • • •
Specifications
Chapter 2 provides specifications for HI 6300 series instruments. The specifications
listed are designed to assist in the installation, operation and troubleshooting of your
instrument. All service personnel should be familiar with this section before installing
or repairing the instrument.
Basic Specifications
General
Number of Channels
•
1 Channel
Update Rate
•
55 Updates per Second
Resolution
•
Internal 1:262,144
WAVERSAVER
•
User Selectable
OFF
7.50 Hz
3.50 Hz
1.00 Hz (default)
Averages
•
1 to 250 User-selectable in Single Increments
Power
•
12-27 VDC
Input
•
Up to four 350-ohm full Wheatstone bridge, strain gauge load sensor/cells (5 volt
excitation) can be connected to the weigh scale input
Non-linearity
•
0.0015% of full scale
Common Mode Rejection
•
110dB at or below 60 Hz
Common Mode Voltage Range
•
2.5 VDC maximum (with respect to earth ground)