Gen2.ids.sl900a.setpassword, Gen2.ids.sl900a.setshelflife, Gen2.ids.sl900a.setsfeparameters – ThingMagic Mercury API v1.23.0 User Manual
Page 53: Gen2.ids.sl900a.startlog, Iso18000-6b tagops, Iso180006b.readdata, Iso180006b.writedata, Iso180006b.readdata 53 iso180006b.writedata 53

Advanced Tag Operations
Level 2 API
53
Gen2.IDS.SL900A.SetPassword
The SET PASSWORD command writes a 32-bit password to the EEPROM. The
password protection for the specified area is automatically enabled if the password is any
other value except 0.
Gen2.IDS.SL900A.SetShelfLife
The SET SHELF LIFE command programs parameters for the dynamic shelf life
algorithm.
Gen2.IDS.SL900A.SetSFEParameters
The SET SFE PARAMETERS command writes the Sensor Front End parameters to the
memory. Those parameters include the range preset values for the external sensor
inputs, external sensor types and the also the sensor that will be used for limits
comparison.
Gen2.IDS.SL900A.StartLog
The START LOG command starts the logging process. It refreshes the data in the
calibration registers, enables the RTC, writes the Start time and sets the Active bit in the
“System status” field in the EEPROM.
ISO18000-6B TagOps
Note
and must be invoked with an Iso180006b.TagData
.
Iso180006b.ReadData
Read the specified number of data bytes starting at the specified byte-offset memory
location.
Iso180006b.WriteData
Write the specified data starting at the specified byte-offset memory location.