beautypg.com

Specifications – Wood’s Powr-Grip PT410AC User Manual

Page 3

background image

Rev 11.3/2-13

1

PT410AC: #35140

SPECIFICATIONS

Model Number:

PT410AC

Description:

Designed for use with a crane or other hoisting equipment, the PT410AC lifter

employs vacuum to hold a load for lifting, and it provides powered 90° tilt

movement for load manipulation.

Power Source:

See serial number plate for specific AC voltage, frequency and amperage.

Vacuum Pads:

Four 10" [25 cm] nominal diameter, concave (Model G0750), standard rubber,

spring-mounted (approx. 1" [2.5 cm] travel), with #60 filter screen

Pad Spread:

17" x 45½" [433 mm x 1157 mm] to outer edges

Load Capacity:

(rated at 16" Hg [-54 kPa] on clean, smooth, nonporous flat surfaces

1

)

Per-Pad

125 lbs [56.5 kg]

Maximum

500 lbs [225 kg]

Lifter Weight:

154 lbs [70 kg]

Tilt Capability:

Powered, 90°; Speed = approx. 6.5 seconds; Duty = 81 tilts per hour

Vacuum Pump:

Rotary vane type, 4 SCFM [113 liters/minute] nominal airflow

or

Diaphragm type, 3 SCFM [85 liters/minute] nominal airflow

Vacuum Reserve Tank: Vacuum reservoir helps prevent immediate vacuum loss in case of power

failure.

Vacuum Gauge:

Dial gauge indicates current vacuum level in positive inches of Hg and negative

kPa.

Vacuum Lift Light:

Green light is energized whenever vacuum level is sufficient for lifting

maximum load weight (higher than 16" [-54 kPa]).

Options:

See separate instructions about optional features.

Operating Elevation:

Maximum = 10,000 feet [3048 meters]

Operating Temperatures: 32° to 100° F [0° to 38° C]
Service Life:

This lifter is designed to have a service life of at least 20,000 lifting cycles,

when used and maintained as intended. Vacuum pads, filter elements and

other wear-out items are excluded; see MAINTENANCE and REPLACEMENT

PARTS LIST for more information. For the D

ISPOSAL OF THE

L

IFTER

after its

service life, see INTENDED USE.

ASME Standard BTH-1: Design Category "B", Service Class "0" (see www.powrgrip.com for more

information)

Wiring Diagram:

The following wiring diagrams are attached for reference in servicing the lifter

or trouble-shooting a deficiency:

700-W01 [W01]

,

700-W02 [W02]

,

716-W01

[A-W01]

,

716-W02 [A-W02]

,

716A-W03 [A-W04]

,

716B-W01 [C-W01]

!!-CE-!! Note: This symbol appears in the

INSTRUCTIONS manual only when requirements of a CE Standard are different from

requirements of other standards that also apply to this vacuum lifter. CE requirements are mandatory in geographical areas
where CE Standards apply, but may be optional in other locations.

1

Load Capacity is based on a friction coefficient of 1; see MAINTENANCE: V

ACUUM

P

AD

M

AINTENANCE

: Friction Coefficient for

additional information.