beautypg.com

Specifications – Wood’s Powr-Grip MTA8LP6FAIR User Manual

Page 3

background image

Rev 2.0/12-12

1

MTA8LP6FAIR: #35096

SPECIFICATIONS

Model Number:

MTA8LP6FAIR

Description:

Designed for use with a crane or other hoisting equipment, the MTA8LP6FAIR

lifter employs vacuum to hold a load for lifting, and it provides mechanically

assisted, manual 90° tilt movements for load manipulation.

Power Source:

Compressed air, 80-150 psi [550-1035 kPa] line pressure, 2 SCFM [57

liters/minute] @ 80 psi [550 kPa]

Vacuum Pads:

Eight 6" [15 cm] nominal diameter, low profile (Model LP6F), standard rubber,

spring-mounted (¼" [7 mm] travel), with #60 filter screen

Pad Spread:

Maximum = 18¼" x 100½" [464 mm x 2556 mm]

(to outer edges)

Minimum

= 18¼" x 37½" [464 mm x 949 mm]

Load Capacity:

(rated at 16" Hg [-54 kPa] on clean, smooth, nonporous flat surfaces

1

)

Per-Pad

= 50 lbs [22.5 kg]

Maximum = 360 lbs [165 kg]

Lifter Weight:

110 lbs [50 kg]

Tilt Capability:

Manual, 90°, with four-bar tilt linkage that minimizes operator effort and

automatically holds a correctly attached load in the upright or flat position

Vacuum Pump:

Venturi type, 1 SCFM [28 liters/minute] nominal vacuum flow @ 80 psi [550 kPa]

Vacuum Reserve:

Vacuum reserve system helps prevent immediate vacuum loss in case of power

failure.

Vacuum Gauge:

Dial gauge indicates current vacuum level in positive inches of Hg and negative

kPa.

Options:

Available

with Model CM3PE2 - 2" [5 cm] Pad Spacers. This option enables the

lifter to handle loads with surface obstructions, such as windows with mullions.

See separate instructions about other options.

Operating Elevation:

Maximum = 13,000 feet [3962 meters]

Operating Temperatures: 0° to 120° F [-18° to 49° C]
Service Life:

This lifter is designed to have a service life of at least 20,000 lifting cycles, when

used and maintained as intended. Vacuum pads, filter elements and other wear-

out items are excluded; see MAINTENANCE and REPLACEMENT PARTS LIST for

more information. For the D

ISPOSAL OF THE

L

IFTER

after its service life, see

INTENDED USE.

ASME Standard BTH-1:

Design Category "B", Service Class "0" (see www.powrgrip.com for more

information)

!!-CE-!! Note: This symbol appears in the

INSTRUCTIONS manual only when requirements of a CE Standard are different from

requirements of other standards that also apply to this vacuum lifter. CE requirements are mandatory in geographical areas
where CE Standards apply, but may be optional in other locations.

1

Load Capacity is based on a friction coefficient of 1; see MAINTENANCE: V

ACUUM

P

AD

M

AINTENANCE

: Friction Coefficient for

additional information.