AINTENANCE

S

CHEDULE

Unless specified elsewhere in this

INSTRUCTIONS

manual, the lifter does not require

maintenance on a routine basis. Instead, maintenance must be performed whenever a

deficiency is indicated by routine inspections or tests. Any maintenance warranted must be
performed before resuming normal operation of the lifter.

B

ATTERY

T

EST

The lifter is equipped with a battery gauge to help the operator evaluate

whether the battery has adequate energy for lifting. Factors such as
the condition of the battery, the time required to execute a lift, and the
porosity of the load combine to determine how much battery energy is

needed.

It is the operator’s responsibility to evaluate these

conditions and to make sure the battery has sufficient energy to

complete a lift safely.

Check the battery energy before every lift and

also at the end of each day's use, to decide whether a charge is needed
(see B

ATTERY

R

ECHARGE

to follow).

15

Never use the lifter when battery

energy registers lower than 50% (that is, when only red lights are illuminated), regardless of the

estimated energy requirement.

WARNING: Never use lifter if battery energy is lower than 50% of capacity.

While the lifter's power switch is in the “ON” position, the battery gauge automatically monitors

battery energy (provided that the lifter is not in stand-by mode). However, the battery gauge
shuts off temporarily while the vacuum pump is running, to prevent an inaccurate reading.
When the pumping cycle is completed, the battery gauge requires a few moments to stabilize

before it displays an accurate energy reading again.
While the lifter's power switch is in the “OFF” position (or the lifter is in stand-by mode), the

battery energy can be checked manually using the battery test button. If the lifter has not been
used since the battery was charged, the battery gauge may falsely indicate an energy level that

is higher than actual, due to a “surface charge” on the battery. After the pump runs for
approximately one minute, the surface charge dissipates, allowing the operator to take an
accurate energy reading.

B

ATTERY

R

ECHARGE

Only use a battery charger supplied by or approved by Wood's Powr-Grip; other chargers may

reduce battery life. Charge the battery as soon as possible after any extended use of the lifter,
or whenever the battery gauge indicates diminished energy (see B

ATTERY

T

EST

preceding).

Temperatures above 70° Fahrenheit [21° Celsius] require the battery to be charged more
frequently.

CAUTION: Charge the battery only while the lifter's power switch is in

the “OFF” position.

Operating the lifter when the charger is connected to an AC power source

could result in permanent damage to the charger.

15

The battery charger must be disconnected from its AC power source in order to test the battery energy; otherwise, the

energy reading on the battery gauge would not be accurate.