Explanation of the functions (part 4) – Waldmann PULSE HFMD version VFC IV - with MFT, Typ I User Manual
Page 21
21
Operating Manual Light Control „PULSE HFMD - Vers. IV“
ENG
Explanation of the functions (part 4)
Function 2.1
Sensitivity high
Function to change the sensitivity
of the presence control.
The function is basically set to
„ON”, i.e., the presence sensor has
a normal sensitivity (100%). Small
movements are also detected
within the detection range of the
sensor.
The presence sensor works with
reduced sensibility (approx. 50%) if
the function is set to “OFF”. Small
movements within the detection
range of the sensor are not de-
tected anymore.
The function can be changed on
lights with sensors XXX /P
Function 2.2
Switch-on automatic
Function to admit or to suppress
automatic switch-on with insuf-
ficient light or in case of presence
(semi-automatic).
The default setting of this function
is ”ON”, i.e., the light is automati-
cally switched on in case of pres-
ence or insufficient light.
The light has to be switched on
manually even in case presence
was detected if the switch-on
automatic is inactive.
The function can be changed on
lights with sensors XXX /P
Fig. 3
Key I
Logo
Light
bar
Key II
LED I
LED II
Function 2.3
Dual sensors
Function for the adjustment of the
operating mode when used with
an additional presence sensor
(optional accessories).
The default setting of this func-
tion is “OFF”, i.e., the switch-on
automatic works when a presence
is detected by one of the two
sensors.
Both sensors must detect a pres-
ence to turn on the light if this
function is active.
The function can be changed on
lights with sensors XXX /P
Note: The functions written in
blue
are not available.