Install the hood, Connect the wiring, Complete installation – Broan RP User Manual
Page 4: Install light bulbs
AP1 & RP SERIES
Page 4
5
Remove
Vertical Duct Knockout or Horizontal Duct
Knockout and attach Damper / Duct Connector with
two (2) screws (supplied).
VERTICAL DUCT
KNOCKOUT
HORIZONTAL DUCT
KNOCKOUT
DAMPER /
DUCT
CONNECTOR
INSTALL THE HOOD
WARNING
To reduce the risk of electrical shock, switch power off
at service panel. Lock or tag service panel to prevent
power from being switched on accidentally.
6
Run
House Power Cable between service panel and
hood location. Attach power cable to hood using appropri-
ate connector.
7
Hold the hood in position under the cabinet. Make sure
the damper / duct connector enters the
Ductwork and
that the damper opens and closes freely.
8
Tighten the four (4)
Mounting Screws completely to se-
cure the hood to the cabinet.
HOUSE
POWER
CABLE
MOUNTING
SCREWS (4)
DUCTWORK
CONNECT THE WIRING
HE0059
9
Connect
House Power Cable to range hood wiring -
BLACK to BLACK, WHITE to WHITE, and GREEN or
BARE WIRE to
GREEN Ground Screw.
HOUSE
POWER
CABLE
GREEN
GROUND
SCREW
10
Re-install the wiring cover, bottom cover, and filters that
were removed in Step 3.
COMPLETE INSTALLATION
11
Install
Halogen Bulbs. Use 120 V, 50 W, shielded halo-
gen bulbs - MR16 or PAR16 with GU10 base. Purchase
bulbs separately.
INSTALL LIGHT BULBS
(1) PUSH IN
(2) ROTATE
CLOCKWISE