AP1 & RP SERIES

Page 2

CLEANING & MAINTENANCE

For performance, appearance, and health reasons, clean filter,

fan and grease-laden surfaces. Use

only a clean cloth and mild

detergent solution on stainless and painted surfaces. Clean all-

metal filters in the dishwasher.

The motor is permanently lubricated and never needs oiling. If

the motor bearings make excessive or unusual noise, replace

the motor with the exact service motor. The impeller should also

be replaced.

Use 120 V, 50 W, shielded halogen bulbs - MR16 or PAR16 with

GU10 base. Purchase bulbs separately.

The grease filters, bottom panel, and blower wheel should be

cleaned frequently. Use a warm detergent solution. The grease

filters and blower wheel are dishwasher safe.

Note: Some minerals, when in contact with dishwasher

soap additives, may cause filters to discolor. This discol-

oration is not covered by the warranty.

PREPARE HOOD LOCATION

SOFFIT

18" - 24" ABOVE

COOKING SURFACE

CABINET

3¼" X 10" DUCT

(For horizontal discharge)

WALL CAP

ROOF CAP

3¼" X 10"

(For vertical

discharge)

HOUSE WIRING

(Top or Back of hood)

HOOD

HOOD

1

Determine whether hood will discharge vertically or hori-

zontally. For vertical or horizontal discharge, run ductwork

between the hood location and a roof cap or wall cap. For

best results, use a minimum number of transitions and

elbows.

OPERATION

Always turn the hood ON before cooking in order to establish an

air flow in the kitchen. After turning off the range, let the hood run

for a few minutes to clear the air.

HEAT SENTRY™
The hood is equipped with a Heat Sentry™ thermostat. This safety

device will turn on or speed up the blower if it senses excess heat

above the cooking surface.
If the blower is not on, or if it is running at low speed, the Heat

Senttry™ will override the normal blower control and trun the

blower on the high speed. When the temperature level drops to

normal levels, the blower will return to its original setting.

RP SERIES HOOD
Operate the hood as follows:

BLOWER SWITCH

This 3-position switch turns blower ON and OFF and controls

blower speed.

Set switch to (1) position to turn blower ON to low speed.

Set switch to (2) position to turn blower ON to high speed.

Set switch to (0) position to turn blower OFF.

LIGHT SWITCH

This 3-position switch turns lights ON and OFF and controls their

intensity.

Set switch to (1) position to turn lights ON to low intensity.

Set switch to (2) position to turn lights ON to high intensity.

Set switch to (0) position to turn lights OFF.

AP SERIES HOOD
Operate the hood as follows:

FAN

The 2-position switch (in center) turns blower ON and OFF.
The 5-position switch (at left) controls blower speed.

Blower is OFF (secondary blower OFF).
Blower is ON at highest speed.

As dots get smaller - blower speed decreases.

LIGHT
This 3-position switch (at right) turns lights ON and OFF and

controls their intensity.

Lights are OFF.
Lights are ON to low intensity.
Lights are ON to highest intensity.

LIGHT

FAN

FAN

ON

OFF