INSTALL THE HOOD
1. Remove the grease filters by pushing filter
towards the back of hood and rotating filter
downward.
2. Remove the metal grille by moving the 2
side fasteners.
3. Cut a hole in the bottom of the cabinet, using
the dimensions shown.
4. Adjust the position of the clasping side spring
by means of the proper screw, according to
the thickness of the panel to which it is going
to be anchored.
5. Insert the hood in the cabinet and lock it by
means of the side spring.
6. Use the holes in the casing of the hood to
attach it using 4 mounting screws.
7. Replace grille and filters.
GREASE FILTERS
METAL GRILLE
10-1/4”
26-5/8”
CUT A HOLE IN THE BOTTOM OF
THE CABINET
min 7-16”
max 13/16”
CLASPING
SIDE SPRING
MOUNTING SCREWS
CONNECT DUCTWORK
1. Connect 8" round metal duct to the
discharge collar on the hood.
2. Use duct tape to make all joints secure and
air tight.
8” ROUND METAL DUCT