PREPARE THE HOOD
Unpack hood and check contents.
You should receive:
1 - Hood
1 - Parts Bag (B080810168) containing:
4 - Mounting Screws (3,2 x 13mm)
1 - Installation Instructions
4 MOUNTING
SCREWS
(3,2 x 13mm)
INSTALL THE DUCTWORK
NOTE: To reduce the risk of fire, use only
metal ductwork.
1. Decide where the ductwork will run
between the hood and the outside.
2. A straight, short duct run will allow the hood
to perform most efficiently.
3. Long duct runs, elbows, and transitions will
reduce the performance of the hood. Use
as few of them as possible. Larger ducting
may be required for best performance with
longer duct runs.
4. Install a exterior blower. Connect round
metal ductwork to exterior blower and work
back towards hood location. Use duct tape
to seal the joints between ductwork
sections.
5. An 8” to 10” transition (Model 414) will be
necessary to connect to the exterior
ventilator.
It is reccommended that the transition be
installed as near to the hood as possible.
HOOD
24” TO 30” ABOVE
COOKING SURFACE
EXTERIOR BLOWER SELECTION
This product is designed for use with the 331H, 332H, 335 or 336 Exterior
Ventilators.
The exterior ventilator must be UL listed for Canadian and U.S. use, and evaluated
for use with solid state speed control rated 120V, 60 Hz, 6.0 A max.
EXTERIOR
BLOWER
8” TO 10”
ROUND
ADAPTER
8” ROUND
DUCT
EXTERIOR
BLOWER
10” ROUND
DUCT
8” ROUND
ELBOW
10”
ROUND
DUCT