beautypg.com

Appendix a - adjusting your autoflush, Operation features, Trouble shooting guide – Rubbermaid 402060 User Manual

Page 2: Activation, Visual indicator guide 1 on 2, Step 4

background image

-

-

+

-

+

+

Use Allen wrench to remove
battery compartment tray.

Remove cover by rotating the
cover up at the end over the
battery compartment and
slide out.

Remove rubber seal.

APPENDIX A - ADJUSTING YOUR AUTOFLUSH

®

TO CHANGE ACTIVATION DISTANCE FOR THE OBJECT LOCK SENSOR:

1

Remove battery compartment. See Step 1.

2

Remove cover. See illustration 4.2.

3

Replace battery compartment in AutoFlush

®

to activate unit and remove rubber seal. See Step 3.

4

Press sensor range reset button as indicated in Appendix A. NOTE: the green L.E.D. will flash continuously
when it has an object in view for the seven minute reset period.

5

Stand at desired activation distance.

6

Use provided sensor adjustment tool and turn Sensor Range Adjustment Screw all the way down (count-
er clockwise) and then turn slowly up (clockwise) until green L.E.D. begins to flash.

7

Ensure Object Lock Sensor is not detecting stall door or wall by closing door, stepping out of sensor path
and making sure green L.E.D. is not flashing. If sensor locks onto door or wall, unit will not flush properly.
Shorten activation distance.

8

Remove battery compartment, and replace cover. Replace battery compartment tray to reactivate
AutoFlush

®

unit.

9

After 7 minute start-up sequence, the green L.E.D. will flash only 3 times when a user is in view
(after a 5 second delay).

1

ON

2

Courtesy Manual

Flush Button

(Toilet Model Only)

Allows manual activation
of flush if needed.

Battery LED (Yellow) Flashing LED = Change Batteries

Object Lock Sensor- Detects User or Object

User-In-View LED (Green) Flashes 3 Times = User acknowledged & ready to operate.

1

ON

2

-

+

Sensor Range

Adjustment Screw

Short

Long

Operation

Features*

Switch 1

24 Hours Flush Off

Switch 2

Alarm Tone Off

Switch 1

24 Hours Flush Off

Switch 2

Alarm Tone On

Switch 1

24 Hours Flush On

Switch 1

24 Hours Flush On

Switch 2

Alarm Tone On

Switch 2

Alarm Tone Off

Sensor Range Reset Button

Sensor Range

Adjustment

1

ON

2

1

ON

2

1

ON

2

1

ON

2

TROUBLE SHOOTING GUIDE

PROBLEM

CAUSE

SOLUTION TO PROBLEM

Green L.E.D.(light) flashes 3
times when there are no users

Green L.E.D.(light) flashes
continuously when Object Lock
Sensor is activated by a user

Yellow L.E.D.(light) flashes

Not enough water to fixture or
too much water to fixture

Flush valve will not operate

Water continuously runs

Unit does not flush even after
Sensor Range has been
adjusted

Front of Object Lock Sensor is covered or Object
Lock Sensor is set too far out,detecting the
opposite wall or door as a user

AutoFlush

®

unit is in 7 minute start up mode

(when first activated) or Sensor Range Reset
Button has been depressed

Batteries are low and need replacing

Flush valve diaphragm damaged or valve
control stop improperly adjusted

Object Lock Sensor range set too close to
AutoFlush

®

,batteries are dead,or water supply

is turned off

Dirt or debris preventing diaphragm from func-
tioning properly

Dead batteries

Remove item covering sensor or adjust Object Lock
Sensor activation distance.(See Appendix A -
Adjusting the AutoFlush)

Green L.E.D.(light) will flash only 3 times
acknowledging a user is in view after the 7 minute
start up mode

Replace batteries. Use ONLY alkaline batteries

Consult flush valve manufacturers directions

Adjust Object Lock Sensor—Replace batteries—Turn
water on.If the AutoFlush

®

does not begin to function,

call (800) 551-5155 for technical assistance.

Consult flush valve manufacturer’s directions

Replace batteries.

Have Questions or Need Supplies?

Call Toll Free: 1-800-551-5155

108112

Your AutoFlush

®

unit comes preset from the facto-

ry. If special circumstances require adjustment of
the activation distance, see Appendix A—
Adjusting Your AutoFlush

®

.

The AutoFlush

®

unit has a 7 minute start-up

sequence in which the Object Lock Sensor will
activate the User-In-View ggrreeeenn LL..EE..D

D..

continu-

ously as long as a user or object is in view. After
the start-up sequence is completed and when the
Object Lock Sensor has a user in view, the User-In-
View ggrreeeenn LL..EE..D

D..

will flash 3 times once the user

is in front of the unit for a minimum of 5 seconds.

ACTIVATION

USER-IN-VIEW L.E.D. (Green light flashes 3 times, after
5 second delay, when a user is in view. The green light
flashes constantly when a user is in view during
the 7 minute start up sequence).

OBJECT LOCK SENSOR
(Detects user or object).

BATTERY L.E.D. (Yellow light flashes
indicating it is time to replace
batteries with 4 new “C” cell alkaline batteries).

COURTESY MANUAL FLUSH BUTTON
(Allows manual activation of
flush when needed—Toilet
model only).

VISUAL INDICATOR GUIDE

1

ON

2

Toll Free: 1-800-551-5155

Web: www.technicalconcepts.com

Email: [email protected]

®

World Headquarters:

Serving North & South America

Technical Concepts LLC.

1301 Allanson Road
Mundelein, Illinois 60060 U.S.A.

☎ 847-837-4100
Fax: 1-800-551-5046

European Headquarters:

Serving Europe, Africa & Middle East

Technical Concepts International Ltd.

Pin Green Business Park Eastman Way
Stevenage, Herts SG1 4UH, England

☎ +44 (0)870 568 6824
Fax: +44 (0)1438 311200

Asian Headquarters:

Serving Asia & Pacific

Technical Concepts Asia

51 (B) Lorong Perindustrian Bukit minyak 9
14100 Bukit Mertajam, Penang, Malaysia

☎ (60) 4 508 5008
Fax: (60) 4 508 5001

4.1

4.2

4.3

Step 4.

This manual is related to the following products: