User programming mode – Water Inc SXT Timer User Manual
Page 17

Page 17
User Programming Mode
User Programming Mode Options
Abbreviation
Parameter
Description
DO
Day Override
The timer’s day override setting
RT
Regeneration Time
The time of day that the system
will regenerate (meter delayed,
timeclock, and day-of-week
systems)
H
Feed Water Hardness
The hardness of the inlet water
- used to calculate system capacity
for metered systems
RC
Reserve Capacity
The fixed reserve capacity
CD
Current Day
The current day of week
NOTES:
Some items may not be shown depending on timer configuration.
The timer will discard any changes and exit User Mode if any button is not pressed for sixty seconds.
User Programming Mode Steps
Press the Up and Down buttons for five seconds while in service, and the time of day is NOT set to 12:01 PM.
Use this display to adjust the Day Override. This option setting is identified by “DO” in the upper left hand
corner of the screen..
.
.
.
.
.
.
Press the Extra Cycle button. Use this display to adjust the Regeneration Time. This option setting is identified
by “RT” in the upper left hand corner of the screen..
.
.
.
.
.
.
Press the Extra Cycle button. Use this display to adjust the Feed Water Hardness. This option setting is
identified by “FH” in the upper left hand corner of the screen..
.
.
.
.
.
.
Press the Extra Cycle button. Use this display to adjust the Fixed Reserve Capacity. This option setting is