3/13/08 Rev. 1

Instruction/ Installation Sheet

DataComm Electronics 4-Gang 110 4x8 Phone Plate &

1x6 Splitter with Tester 70-0078

Telephone Installation

 Locate the central point where all telephone home runs meet.
 Install either a 4-gang mounting bracket or a 4 gang switch box at the central

point where the telephone wires come together.

 Install the cable from the telephone company demarcation point to the top 110

IDC on the plate.

 Install the remaining twisted pair cables from each location in the house to the

remaining 110 IDC connectors. Match the color-coding of the wires to the colors
on the 110 IDC connectors. To connect phone service, insert the three inch
patch cord into the Telco port and the Home port. Incoming service can be tested
using the Telco port.

 The wires should be punched down, using an industry standard punch-down tool,

to the 110 IDC connectors following the T568A wiring configuration as shown
below.

 Secure the plate to either the mounting bracket or switch box.
 Line 1 is Blue, Line 2 is Orange, Line 3 is Green and Line 4 is Brown.

White / Blue

Blue

White / Orange

Orange

White / Green

Green

White / Brown

Brown

Video Installation

 Attach a male F-connector onto the cable TV service or satellite service incoming

cable. Screw the incoming cable with F-connector to the connector marked
input.

 Using F-connectors, terminate all coaxial leads that have been pulled through the

four gang in the wall to the remaining connectors on the splitter.