Progressive International Electronics RLM 2 User Manual
Page 9
RLM Systems Installation Guide
Version 3.0 © November 2008
3
SYSTEM INSTALLATION
Description of RLM Components
The RLM systems are made up of the components listed below. Using this checklist, identify
and familiarize yourself with each of the components in your shipment. (For further
clarification, refer to the block diagrams at the end of each section in the Dispenser Specific
Installation portion of this manual.)
COMPONENT CHECKLIST
RLM II
(Electronic)
U RLM II Main Box
Power transformer and connector for
dispenser communication cable.
U Dispenser Communication Cable
Cable which connects the RLM II box
to the fuel dispenser distribution box.
U Installation Manual
RLM
(Mechanical)
U RLM Main Box
With communication cable to Tank
Monitor, power transformer and
connector for dispenser communication
cable.
U Installation Manual
U System/Test Diskette
RLM II and RLM Mechanical General Specifications
Physical Size
7.5" x 8.5" X 2"
Operating Temperature
32 to 120 degrees F
Storage Temperature
32 to 120 degrees F
Electrical Requirements
115VAC, 20 W Maximum (dedicated
circuit with earth bond)