Progressive International Electronics RLM 2 User Manual
Page 26
RLM Systems Installation Guide
Version 3.0 © November 2008
20
RLM II for ELECTRONIC DISPENSERS
Diagnostics
Features and Operation of the RLM II Diagnostic Port
Extensive testing and data collection is available to the user through the RLM II’s built-in
diagnostic port, which is physically located on the front panel of the RLM II. See Diagram:
RLM II Front Panel below. Accessing the diagnostic port requires a computer running a
terminal emulation program such as Hyperterm or Procomm. Physical connection is made
using a serial cable (straight through). Once the connection is established, power up the
RLM II and a prompt will appear. To view a help menu, type a ? at the prompt.
The terminal emulation program (Hyperterm or Procomm) must be set to the following
parameters to work properly.
Baud rate
57,600
Data bits
8
Parity
none
Stop bits
1
Flow control
none
Terminal emulation
setting
ANSI