Innotech Systems SpitFIRE II User Manual
Page 14

SpitFIRE
Innotech Systems Inc.
Page 14
1 0 Visible LED flash count
1 1 Status message
DAT3-0
Status messages (MOD=11)
0000 NOP
0001 This scancode is not currently used
0010 The selected device number is not in the database
0011 This button is not implemented on the selected device.
0100 No source programmed
0101 Programming sequence aborted
0110 IR transmission complete
0111 Database error
1000 SpitFIRE has been reset
1001 Auto search mode
1010 No learn location specified
1011 No IR detected in learn mode
1100 Press button to specify learn location
1110 Invalid code
1111 Could not learn button
DAT3-0
LED flashes in BCD (0-9)
DAT3-0
Software revision code (0-31) Uses MOD0 as a 5th bit.
For example, assume that a VCR was previously programmed as Source 1. To select the source and
press the POWER button:
System sends
C1h
Select VCR (source #1)
System gets
21h
Return 1 flash
System sends
D2h
Transmit IR 2 times mode
System gets
21h
Return 1 flash
System sends
96h
Press the POWER button
System gets
36h
IR Transmission complete (after a delay)
The source selection and transmission instructions stay in effect until they are changed.