Wabco blink codes – IPA Tools 9005A Super MUTT Head User Manual
Page 24
24
Blink
Code
3
4
5
6
7
9
10
11
14
15
16
17
18
Problem
Area
Sensor BUI
Sensor YEI
Sensor BU2
Sensor YE2
External ABS
Modulator Valve
Internal modulator
failure inlet valve #2
Internal modulator
failure inlet valve #1
Internal modulator
failure inlet valve
Power Supply
ECU Failure
SAE JI 708 Failure
SAE J2497
(PLC) Failure
Generic I/O Failure
Determine sensor location. Check sensor installation.
Make necessary repairs.
Determine sensor location. Check senor installation.
Make necessary repairs.
Determine sensor location. Check sensor installation.
Make necessary repairs.
Determine sensor location. Check sensor installation.
Make necessary repairs.
Verify proper electrical modulator installation.
Check power supply. Make necessary corrections.
Verify proper installation. If code continues, contact
Meritor WABCO for assistance.
Verify proper installation. If code continues, contact
Meritor WABCO for assistance.
Verify proper installation. If code continues, contact
Meritor WABCO for assistance.
Verify proper electrical installation. Check power supply.
Make necessary corrections.
Verify proper installation. If code continues, contact Meritor
WABCO for assistance.
Internal failure, contact Meritor WABCO
Internal failure, contact Meritor WABCO
Verify proper electrical installation. Check power supply.
Make necessary corrections.
Action
For diagnostic and troubleshooting assistance, call Meritor WABCO at 1-800-535-5560
WABCO BLINK CODES
Select AUX circuit, depress control knob to flash brake lights in sequence.