15. TROUBLESHOOTING (cont)

The pump does not deliver the rated flow / is noisy:

• Insufficient feeding (see the causes listed above)

• RPM are less than the rated value

• Excessive amount of water by-passed by the pressure adjustment valve

• Worn valves

• Leakage from the pressure packings

• Cavitation due to:

1) Wrong sizing of the suction hose/ undersized diameters

2) Insufficient flow rate

3) High water temperature

Insufficient pump pressure:

• The nozzle (or has become)too large

• Insufficient RPM

• Leakage from the pressure packings

• Incorrect operation of the pressure adjustment valve

• Worn valves

Overheated pump:

• The pump is overloaded (pressure or RPM exceed the rated values)

• Oil level is too low, or the oil is not of a suitable type, indicated in Chapter 7 (see paragraph 7.4)

• Incorrect alignment of the joint or pulleys

• Excessive inclination of the pump during operation

Pump vibrations or knocking:

• Air suction

• Incorrect operation of the pressure adjustment valve

• Valve malfunction

• Irregular drive transmission motion