In case the pump has not run for a long period of time, verify the correct operation of the suction and

delivery valves.

10.2 Start-up

1. When starting the pump for the first time, check for the correct direction of rotation.

2. The pump must be started off-load.

3. Verify correct feeding pressure.

4. During operation, check that the rotating speed does not exceed the rated value.

5. Before putting the pump under pressure let it run for at least 3 minutes.

6. Before stopping the pump, release the pressure by acting on the adjustment valve or on any discharging

device.

11. PREVENTIVE MAINTENANCE

PREVENTIVE MAINTENANCE

EVERY 500 HOURS

EVERY 1500 HOURS

Check oil level

Change oil

Check / Replace:

• Valves

• Valve seats

• Valve springs

• Valve guides

Check / Replace:

• H.P packings

• L.P. packings

To guarantee pump reliability and efficiency, respect the maintenance intervals as indicated in the table below.

12. STOPPING THE PUMP FOR LONG PERIODS

12.1 Inactivity For Long Periods

If the pump is started up for the first time after a long period from the shipment date, before starting operation

check the oil level, check the valves as indicated in Chapter 10, and follow the start-up procedures described.

12.2 Filling the Pump With An Anti-Corrosion Emulsion or Anit-freeze By Using An External Diaphragm

Pump As In The Layout Shown in Paragraph 9.7.

a) Close the filter draining, if open.

b) Be sure that the connecting hose is clean, spread with grease and connect it to the high pressure outlet

port.

c) Fit a suction hose to the membrane pump. Open the pump suction connection and fit hose between it and

the membrane pump.

d) Fill the container with the solution/emulsion.

e) Put the free extremities of the suction line and the high pressure outlet hose inside the container.

f) Start up the diaphragm pump.

g) Pump the emulsion until it comes out of the high pressure hose.

h) Continue pumping for at least another minute; if needed, the emulsion can be reinforced by adding, for

example, Shell Donax

i) Stop the pump, remove the hose from the suction connection and close it with a plug.

j) Remove the hose from the high pressure outlet port. Clean, grease and plug both connections and the

hoses.