2 rs232c display / edit mode – FEC MICRO NR User Manual
Page 91

FEC Micro Nutrunner Operations Manual
Chapter 7: System Operations (Rev. 2.1: 12/12)
Page 7-23
7.4.2 RS232C Display / Edit Mode
Select RS-232c port either Printer or User-console mode. 
Depressing the SET button will initiate the preset edit mode and a blinking data will appear in the 
[DATA] display. The blinking character can be change (select) by using the [
] and [
] buttons.
This operation requiring Data confirmation and Power off and on cycle. (Check detail section)
 
 
 
 
User-console mode
 
 
 
 
 
 
 
 
 
Fastening data output mode
 
 
 
 
 
 
 
Select Fastening data output mode when using USB User-Console communication. 
 
 
 
 
 
 
[
], [
]
Button
Set to “UC” to enable User 
Console software communication 
through the RS232 port. 
This setting disables User Console 
communication through the USB 
port. 
Set to “Prt” to enable data output 
to an external device (IE: printer, 
PLC, etc.) through the RS232 port. 
This setting enables User Console 
communication through the USB 
port. 