Dimensions, Product data submittal, Low emissions burner) – Fulton Edge ICX or FB-F Vertical Tubeless Boilers (Steam), Gas Fired User Manual
Page 15: Fulton models: ics/fb-a and icx/fb-f
Standard Models ICS/FB-A
9.5
10
15
20
25
30
Models ICX/FB-F
9.5
10
15
20
30
Unit Size:
BHP
9.5
10
15
20
25
30
A. Boiler Height
IN
67.5
63.5
69
72.5
74.5
82
MM
1715
1613
1753
1842
1892
2083
B. Boiler Height With Trim*
IN
85
80.5
93
97
97
106.5
& Fuel Train Assembly
MM
2159
2045
2362
2364
2364
2705
C. Overall Depth Stack
IN
44
48
50
61
59
65.5
to Burner Fan Housing
MM
1118
1219
1270
1549
1499
1664
D. Boiler Diameter
IN
26
28
30
39
39
46
MM
660
710
760
990
990
1170
E. Overall Width
IN
33
33.5
35.5
43
43
49
with Water Column
MM
838
851
902
1091
1091
1244
F. Flue Outlet Diameter
IN
6
6
8
10
10
12
MM
152
152
203
254
245
305
G. To Center of Flue Outlet
IN
61.5
57.5
63
66
68
73
MM
1562
1465
1600
1675
1728
1854
H. Feedwater Inlet
IN
33
33
33
34
34
34
MM
838
838
838
865
865
865
I. Handholes
IN
18.5
18.5
19.5
19.5
19.5
19.5
MM
470
470
495
495
495
495
J. Blowdown Outlet
IN
15.25
15
15
16.5
16.5
16.5
MM
387
381
381
420
420
420
K. Water Column Extension
IN
14
14
14
14
14
14
MM
355
355
355
355
355
355
L. Gas Train Extension
IN
25
21.5
20.5
25
25
27
(CSD-1)
MM
635
546
521
635
635
686
M. Clearance Required
IN
94
86
108
111
110
121
for Burner Removal
MM
2388
2184
2743
2819
2794
3073
Weights
Approx. Shipping Weight
LB
1900
2000
2280
3400
3500
4780
KG
862
910
1036
1545
1591
2173
All measurements are subject to +/- 0.5”. Please refer to component drawings for actual measurements.
NOTE: Recommended minimum clearance is 24” to the side and back of unit; 36” in front
Dimensions
Fulton Gas & Oil Fired
Vertical Tubeless
Steam Boilers
(Low Emissions Burner)
Product Data Submittal
Fulton Models: ICS/FB-A and ICX/FB-F
B
I
J
ON/OFF GAS HEAD
CAN PIVOT 360°
MODULATED GAS HEAD IS
FIXED ABOVE FAN HOUSING
CLEARANCE REQUIRED FOR
BURNER REMOVAL
E
Top View
Front View
Side View
K
P
N
F
A
M
S
H
R
Q
O
G
C
D
L