beautypg.com

Iv. grounding instructions, V. technical specifications, Warning – Gardner Bender BV208DA User Manual

Page 4

background image

4

IV. Grounding Instructions

The GB/JetLine

®

blowers and Blo-Vac™

systems require a 120V, 60Hz, 15A circuit; with
the exception of the B3000 power unit which
requires a 120V, 60Hz, 30A circuit; and must be
grounded. If the power unit should malfunction
or breakdown, grounding provides a path of
least resistance for the electrical current to
reduce the risk of electrical shock. These power
units are equipped with a cord that has a
grounding conductor and grounding plug. The
plug must be inserted into an outlet that is
properly grounded in accordance with all codes
and ordinances. FIG. 1

V. Technical Specifications

Catalog No.

B45

B60

Power Unit

1261

B3000

Voltage

120

120

Frequency

60Hz

60Hz

AMPS

7.50

23

In. Water Lift

(sealed)

85-92

85-92

P.S.I.

3.31

3.31

CFM

90

270

No. of Motors

1

3

Impeller Stages (Fans)

2

2

Thermal Overload

Yes

Yes

Motor Type (Cooling)

Flow Through Flow Through

Handling

Portable

Portable

Weight

7.5 lb.

35 lb.

Hose Dia. (Inch)

1

1

2

2

1

2

Length (Feet)

3

25

Catalog No.

BV208DA

Power Unit

1523

Voltage

120

Frequency

60Hz

AMPS

13.8

Inches Water Lift (sealed)*

130-135

P.S.I. *

4.86

CFM

92

No. of Motors

1

Impeller Stages (Fans)

3

Thermal Overload

No

Motor Type (Cooling)

By-Pass

Handling

Cart

Recovery Cap. (Gals)

9**

Height with Cart (Inch)

41

Motor Brush Life (Hours)

750

Weight

50 lb.

Hose Dia. (Inch)

1

1

2

Length (Feet) ***

8

*

Will vary with voltage and atmospheric conditions.

**

When using recovery compartment and tool storage
compartment together.

***

Optional 15 ft. hose available, catalog #125615

Improper connection of the equipment grounding conductor can result in a risk of electrical shock. Check with a
qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not
modify the plug provided with the Blo-Vac™. If it will not fit the outlet, have the correct outlet installed by a
qualified electrician.

FIG. 1

Grounding

Pin

Grounded

Outlet Box

Adapter

Metal

Screw

Tab for

Grounding

Screw

Grounding

Blade

Grounding Methods

125V

30A

NEMA

L5-30R

Table 1

GB/JetLine Blowers

Table 2

GB/JetLine Blo-Vac™

!

WARNING

RPS-0134 3/29/00 2:10 PM Page 4

This manual is related to the following products: