Iv. grounding instructions, V. technical specifications, Warning – Gardner Bender BV208DA User Manual
Page 4
4
IV. Grounding Instructions
The GB/JetLine
®
blowers and Blo-Vac™
systems require a 120V, 60Hz, 15A circuit; with
the exception of the B3000 power unit which
requires a 120V, 60Hz, 30A circuit; and must be
grounded. If the power unit should malfunction
or breakdown, grounding provides a path of
least resistance for the electrical current to
reduce the risk of electrical shock. These power
units are equipped with a cord that has a
grounding conductor and grounding plug. The
plug must be inserted into an outlet that is
properly grounded in accordance with all codes
and ordinances. FIG. 1
V. Technical Specifications
Catalog No.
B45
B60
Power Unit
1261
B3000
Voltage
120
120
Frequency
60Hz
60Hz
AMPS
7.50
23
In. Water Lift
(sealed)
85-92
85-92
P.S.I.
3.31
3.31
CFM
90
270
No. of Motors
1
3
Impeller Stages (Fans)
2
2
Thermal Overload
Yes
Yes
Motor Type (Cooling)
Flow Through Flow Through
Handling
Portable
Portable
Weight
7.5 lb.
35 lb.
Hose Dia. (Inch)
1
1
⁄
2
2
1
⁄
2
Length (Feet)
3
25
Catalog No.
BV208DA
Power Unit
1523
Voltage
120
Frequency
60Hz
AMPS
13.8
Inches Water Lift (sealed)*
130-135
P.S.I. *
4.86
CFM
92
No. of Motors
1
Impeller Stages (Fans)
3
Thermal Overload
No
Motor Type (Cooling)
By-Pass
Handling
Cart
Recovery Cap. (Gals)
9**
Height with Cart (Inch)
41
Motor Brush Life (Hours)
750
Weight
50 lb.
Hose Dia. (Inch)
1
1
⁄
2
Length (Feet) ***
8
*
Will vary with voltage and atmospheric conditions.
**
When using recovery compartment and tool storage
compartment together.
***
Optional 15 ft. hose available, catalog #125615
Improper connection of the equipment grounding conductor can result in a risk of electrical shock. Check with a
qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not
modify the plug provided with the Blo-Vac™. If it will not fit the outlet, have the correct outlet installed by a
qualified electrician.
FIG. 1
Grounding
Pin
Grounded
Outlet Box
Adapter
Metal
Screw
Tab for
Grounding
Screw
Grounding
Blade
Grounding Methods
125V
30A
NEMA
L5-30R
Table 1
GB/JetLine Blowers
Table 2
GB/JetLine Blo-Vac™
!
WARNING
RPS-0134 3/29/00 2:10 PM Page 4