background image

17

SECTION HEAD

Life Safety Interface 16e SPECIFICATIONS

System Fault Relay:

Type:

Load:
Maximum operating voltage:
Maximum operating current:
Maximum switching capacity:
Minimum permissible load:

Single ‘Form C’ voltage-free SPST

change-over contact

Resistive

125VAC, 60VDC

600mA AC, 1A DC

37.5VA, 30W

10µA @ 10mVDC

RS232 Port

Type:
Baud Rate:

DTE

57600

Connection:

RJ45 with shielded Ethernet/PoE cable

(CAT5, CAT5e, CAT6 or CAT7)

Control Inputs:

Number:
Type:
Cathode presented at input –
pull low to enable. Sink Current:
Min:
Max:
Maximum Terminal Voltage:
Isolation:

Eight

Opto Isolator LED

1mA
6mA

24V

3kV

Power:

Main:
PoE:

24V DC 15W

802.3af Class 3

Base Dimensions:

Height:
Width:
Depth:

1.75 inches (44.5mm)

19 inches (483mm)

10 inches (254mm

Monitored I/O:

Number:
Type:

Maximum Continuous Current:
Current Limit:
Maximum External Supply:
VMon Input Shutdown:

Option Inputs:

Number:
High Range Logic Low:
High Range Logic High:
High Range Hysteresis:
TTL Logic Low:
TTL Logic High:
TTL Hysteresis:
Input Transient Protection:
Input Isolation:

Eight

FET switch, open drain (low

side driver)

0.35A

0.8A

35V
35V

16

0-11 DC

12-30 DC

1V ± 20%

0-0.8V

2-5V

1V ± 20%

± 8KV peak

500V RMS (isolation from LSI-16)

Weight:

Approx 6.4 lbs. (2.8kg)

Ambient Operating
Temperature Range:

32-113 degrees F (0-45 degrees C)

Compliance:

FCC Part 15, class B

CE marked

EN 54-16 certification pending

RoHS Directive

UL 60065 Listed, E215636

C-UL Listed, E215636

C-Tick, N24138 (Australia)

Life Safety Interface 16e BLOCK DIAGRAM

LSI-16e SPECIFICATIONS

LEDs

Vocia

System

24V DC

PoE

8 Control Inputs

8 Monitored Outputs

16 General Purpose

Inputs

ID Switches

Host Processor