Flow meter communications & direction of flow – Fill-Rite TS SS F & W Precision Meter User Manual

Page 8

background image

Direction of Flow

TS Series flow meters can operate in either direction.
Standard assembly, when facing the flow meter, has the
flow going Left-to-Right, unless specified differently at time
of the order. A label with the word INLET is placed on the
inlet flange, as assembled at the factory. To change the
direction of flow:

1. Reverse the position of any accessories attached to the

flow meter.

2. If Quadrature pulse signal is used, reverse output leads

for channels A & B on the TBB (or SCL):

TBB

SCL

L-to-R R-to-L

WHITE: On A On B

GREEN: On

B

On

A

NOTE: The ELNC register is not W&M certified in
the EU.

The SCL is not yet approved for use in
the EU.

1 . 8

Flow Meter Communications & Direction of Flow


TS Series meters in F●● & W●● assembly have an internal
pulser. The pulse signal generated by the flow meter, can
be fed directly to most electronic registers. In such assem-
blies, flow meter calibration (or re-calibration) is through
correction of the K Factor (number of pulses/unit volume) in
the electronic register.

In some cases an SCL board (#13) is added to the flow me-
ter assembly. This signal conditioner is added when:

1.

Flow meter pulse frequency exceeds the electronic
register capacity at maximum flow rate. This can occur
at surprisingly low flow rates (see below).

2.

The electronic register requires a scaled pulse value
(1, 10, 100 or 1000 pulses/volume unit).

3.

Local authorities demand a mechanical calibration de-
vice. The SCL includes two dials with setting from 00
to 99. Changing the setting by 1, represents approx.
0.03% correction to the pulse signal.


NOTE: K Factors shown here are nominal (average).

Individual flow meters can vary slightly; and all flow
meters will shift to some degree with viscosity fluctu-
ations (see page 1.14)

Register m odel:

LCR-II™

Frequency lim it:

625 Hz

FLOW

METER

MODEL

GPM LPM

P P G ppl

TS10C

40

150

2176 575

1451

Hz

0.35

ms

TS15C

60

230

1152 304

1152

Hz

0.43

ms

TS20C, NS 150

570

395 104

988

Hz

0.51

ms

TS30C,

200

760

276

73

920

Hz

0.54

ms

Interm. duty

250

945

1150

Hz

0.44

ms

Interm. duty

300 1135

1380

Hz

0.36

ms

With EL0300-3-13 = 100 PPG scaler

TS10C

40

150

100

26

67

Hz

1.30

ms

TS15C

60

230

100

26

100

Hz

1.30

ms

TS20C, NS

150

570

100

26

250

Hz

1.30

ms

TS30C,

200

760

100

26

333

Hz

1.30

ms

Interm. duty

231

875

385

Hz

1.30

ms

If higher flow rates occur, use EL0300-3-18 (see below)

With EL0300-3-18 = 10 PPL scaler

TS10C

40

150

37.9 10

25

Hz

2.50

ms

TS15C

60

230

37.9 10

38

Hz

2.50

ms

TS20C, NS

150

570

37.9 10

95

Hz

2.50

ms

TS30C,

200

760

37.9 10

126

Hz

2.50

ms

Interm. duty

250

945

158

Hz

2.50

ms

Interm. duty

300 1135

189

Hz

2.50

ms

EMR

3

Please refer to FPP261 for other registers.

ELNC

400 Hz

CAPACITY K Factor

Frequency (Hz) &

Pulse ON time at

100% of model cap.

1667 Hz