beautypg.com

W_4 w_5, W_6 f_4 f_6 f_5, Assy no – Fill-Rite TS SS F & W Precision Meter User Manual

Page 5: Flow meter assembly no. & part no, W_x = without register flange, Pos. 6-8 in p/no.), F_x = with register mounting flange

background image

Flow Meter Assembly No. & Part No.

Model No. + Assy. No. + Variable Identifiers = Part No.
Model No. : 5 digits; referenced in certifications, etc.
Assy. No. : 3 digits, define basic type & configuration
Variables : Identified in remainder of the Part No.

The Part No., is found on flow meter Spec Plate, together
with the Serial No. The P/No. can be as short as 8, or as
long as 18 positions; where each position has some signifi-
cance. The key identifier for the purpose of identifying spare
parts is in all cases Pos. 10 which identifies flow meter inter-
nals:

B

= LV, PPS/carbon rotors, Teflon seals (standard)

C

= HT, PPS/carbon rotors, Teflon seals

D

= HV, PPS/carbon rotors, Teflon seals

E

= LV, PPS/Teflon rotors, Teflon seals

P

= HT, PPS/Teflon rotors, Teflon seals

H

= HV, PPS/Teflon rotors, Teflon seals

If it is necessary to replace the board found in the pulser
compartment in the front cover, the key identifiers are:

Fxx

assemblies, Pos. 11:

5-12VDC 24VDC

1-9 or T

same

: EL0304

Terminal

Block

Board

G H : EL0300-3-13_ 100 PPG scaler
L K : EL0300-3-18_ 10 PPL scaler
A A : EL0305

TBB/Amplifier

F J

: EL0306

TBB/Quadrature

Filter

Wxx

assemblies, Pos. 12:

5-12VDC 24VDC

T T

: EL0304

Terminal

Block

Board

G H : EL0300-3-13_ 100 PPG scaler
L K : EL0300-3-18_ 10 PPL scaler
A

A : EL0305

TBB/Amplifier

F J

: EL0306

TBB/Quadrature

Filter

Fxx = Flow Meter

with Register Mounting flange

:

Position 1-5 : Model No. (capacity & materials)

Position

6

: F = Electronic, with mounting flange

Position 7 : Register included, if any
Position

8

: Accessories included, if any

Position

9

: Flange

type

Position 10 : Rotor type, Bearing Material & Seals
Position 11 : Register & Printer included
Position 12 : UL or ATEX listed components
Position 13 : Register language
Position 14 : Strainer identifier
Position

15 : Strainer basket mesh identifier

Pos. 16-17 : Solenoid valve type & voltage
Position 18 : no significance at this time

Wxx = Flow Meter

without Register Mounting flange

:

Position 1-5 : Model No. (capacity & materials)

Position

6

: W = Electronic, without mounting flange

Position 7 : Register included, if any
Position

8

: Accessories included, if any

Position

9

: Flange

type

Position 10 : Rotor type, Bearing Material & Seals
Position 11 : Internal signal conditioner, if any
Position 12 : UL or ATEX cable gland, if any
Position 13 : Register enclosure, if any
Position 14 : Strainer identifier
Position

15 : Strainer basket mesh identifier

Pos. 16-17 : Solenoid valve type & voltage
Position 18 : no significance at this time

1 . 5

1 = Register Ready (no register from Tuthill)
5 = with EMR3 register, without Temp probe.
6 = with EMR3 register, with Temp probe

(select strainer with thermo well if ATC)

7 = with SCL & ELNC register

W_X = without register flange

0 = Flow Sensor (nothing attached)
1 = 1x PIA-300 amplifier (2 x single channel)
2 = 2x PIA-300 amplifier (1 x Quadrature)
3 = PC58
4 = PC58 + PIA-300
5 = PC58 + 4-20 mA signal
6 = PC58 + 4-20 mA signal + multipoint calibration
7 = PC58 + 4-20 mA + PIA-300

Assy No.

(pos. 6-8 in P/No.)

W_4 W_5

Pos. 7 identifier inserted from list below

METER

+ STRAINER

+ AIR ELIM.

F_X = with Register mounting flange

W_6

F_4

F_6

F_5