Wiring to Low Frequency Quadrature Register/Controller
1 . 10
C. EL0300 Scaler/Calibrator/Linearizer (SCL)
While the SCL can have multiple functions, in many
cases it is included strictly as a signal conditioner
(= ‘Jitter filter’). In those cases, only the calibrator
function is active.
Pulser plug is removed. Pulser leads are connected
directly to TB2 on the SCL.
Signal output cable is connected to TB1.
This diagram applies to the ELNC register, when the
flow meter/register are used
in non-hazardous zone
.
It also applies to LectroCount™ and other lower fre-
quency registers with quadrature input.
D. EL0300 (SCL), EL2057 Energy Limited Power Supply (ELPS) & ELNC Register
When flow meter/ELNC register is
used in a hazardous zone, the
EL2057 (AC/DC power supply &
barrier, UL listed) must be used.
EL2057 is in a NEMA 7 enclosure
(Expl-Proof, but not water proof), so
it must be installed under roof or
inside a water proof cabinet.
Pulser plug is removed. Pulser
leads are connected directly to
TB2 on the SCL.
Signal output cable is connected
to TB1.
Note 1
: See CD1000 & CD1001 for installation of intrinsically safe apparatus.
Note 2
: Cable lengths are limited by entity parameters.
Note 3
: ELPS output option: Install U1, R3 & TB6.
E. EL0300 to non-Quadrature Register
Same as diagram D, but connect only signal channel A.
EL5591
or
EL0303
SCL is not yet approved
for use in the EU
.
SCL is not yet approved
for use in the EU
.
SCL is not yet approved