Wiring to Low Frequency Quadrature Register/Controller

1 . 10

C. EL0300 Scaler/Calibrator/Linearizer (SCL)

While the SCL can have multiple functions, in many
cases it is included strictly as a signal conditioner
(= ‘Jitter filter’). In those cases, only the calibrator
function is active.



Pulser plug is removed. Pulser leads are connected
directly to TB2 on the SCL.



Signal output cable is connected to TB1.

This diagram applies to the ELNC register, when the
flow meter/register are used

in non-hazardous zone

.


It also applies to LectroCount™ and other lower fre-
quency registers with quadrature input.

D. EL0300 (SCL), EL2057 Energy Limited Power Supply (ELPS) & ELNC Register

When flow meter/ELNC register is
used in a hazardous zone, the
EL2057 (AC/DC power supply &
barrier, UL listed) must be used.
EL2057 is in a NEMA 7 enclosure
(Expl-Proof, but not water proof), so
it must be installed under roof or
inside a water proof cabinet.



Pulser plug is removed. Pulser
leads are connected directly to
TB2 on the SCL.



Signal output cable is connected
to TB1.



Note 1

: See CD1000 & CD1001 for installation of intrinsically safe apparatus.

Note 2

: Cable lengths are limited by entity parameters.

Note 3

: ELPS output option: Install U1, R3 & TB6.


E. EL0300 to non-Quadrature Register

Same as diagram D, but connect only signal channel A.

EL5591

or

EL0303

SCL is not yet approved

for use in the EU

.

SCL is not yet approved

for use in the EU

.

SCL is not yet approved

for use in the EU

.