Install the Chassis Rails
Position the fixed chassis rail sections you just removed along the side of the server
chassis making sure the five screw holes line up. Note that these two rails are left/right
specific. Screw the rail securely to the side of the chassis. Repeat this procedure for the
other rail on the other side of the chassis. You will also need to attach the rail brackets
when installing into a Telco rack.
Locking Tabs: As you have seen, both chassis rails have a locking tab, which serves
two functions. The first is to lock the server into place when installed and pushed fully
into the rack, which is its normal position. Secondly, these tabs also lock the server in
place when fully extended from the rack. This prevents the server from coming com-
pletely out of the rack when you pull it out for servicing.
Install the Rack Rails
Determine where you want to place the server unit in the rack. Position the fixed rack
rail/sliding rail guide assemblies at the desired location in the rack, keeping the sliding
rail guide facing the inside of the rack. Screw the assembly securely to the rack using
the brackets provided. Attach the other assembly to the other side of the rack, making
sure that both are at the exact same height and with the rail guides facing inward.