TroubleShooting

DIAGNOSTIC LED’

S

The Red LED indicates that the amplifier is on.

The Yellow LED indicates that an over-current condition (low imped-
ance) exist and will turn the amp’s output power down to maintain unin-
terrupted operation. The Yellow LED will light if a speaker load falls
below the M Series’ 2

rating and/or a speaker lead / speaker voice coil

is shorted.

The Orange LED indicates that an over-heating condition exists and will
turn the amp’s output power down to maintain uninterrupted operation.
The Orange LED will light if the heatsink temperature exceeds rated
spec due to poor ventilation.

Symptom/Condition

Cause

Solution

Red LED not on. No Sound.

Loss of 12V Power at Amplifier

Check out-board fusing

Check +/– 12 Volt connections

Measure for + 12 Volts or higher

@ amp. Check Turn-On lead

Red LED on. No Sound.

No Input Signal

Check integrity of RCA cables

Check connection at amp and

head unit.

Red LED on. No Sound.

Loose Speaker Wires

Check integrity of speaker

connection at amp and speakers.

Red LED on. No Sound.

Lack of Turn-On Voltage

Voltage @ Turn-On lead needs

to be 8 Volt minimum

Red LED on. No Sound.

Missing Accessory Port Jumper

Check Port Jumpers, two jumpers

per port are required. Check

jumper alignment, jumper must

be seated properly.

Red LED on. No Sound.

Accessory module is not

Be sure “key” on module connector

installed properly

and port are aligned when

installing module. Reseat module

to insure proper connection.

Alternator/System Noise

Induced noise / ground loop

“Enable” Balanced Input