Ultimate Technology 500 POS User Manual
Page 65
57
2. At the source keyboard, swipe the Programmer's card in the magnetic stripe reader (MSR).
For keyboards equipped with an optional 3-position keyswitch adjacent to the LED
indicators, set the switch to the AUX position, then enter 882 at the numeric keypad.
3. All LED indicators turn on and the keyboard enunciator beeps three times.
4. At the source keyboard numeric keypad, enter 98.
5. Exit the local programming mode by typing 99 on the source keyboard numeric keypad or
by swiping the Programmer's card. For keyboards equipped with an optional 3-position
keyswitch, move the switch out of the AUX position. This returns the keyboard to normal
operation.
6. Repeat steps 1 through 5 for next target keyboard or disconnect equipment.
OPERATOR'S AND PROGRAMMER'S MAGNETIC CARDS
Operator's and/or Programmer's magnetic cards are available for purchase from Ultimate
Technology Corporation should the need for replacement or customized cards be required.
SYSTEM LOG
The Series 500 POS Keyboard maintains a system log to monitor and record both external and
internal operating events. When Function Code 90 is entered at the keyboard, this system log
data is transferred via the keyboard main port to a terminal/PC for monitoring or for capture as a
data file. Refer to Table 2 for instructions needed to initiate Function Code 90.