Ultimate Technology 500 POS User Manual
Page 34
26
Table 3. Local Mode Programming Instructions - Continued
Note: *Default Settings
Function Code(s)
Operation
Normal Indication
Remarks
25 or 35
Comm (RS232)
Main Port 0 (25)
AUX Port 1 (35)
Prefix
1. While in programming mode, at the Series 500 Keyboard numeric keypad,
enter applicable Function Code 25 (Port 0) or 35 (Port 1).
LED (2) flashes.
2. At the auxiliary keyboard, press the desired key or type the desired key
sequence. Note that the maximum number of key codes is limited to 24 - this
is equivalent to approximately 12 key strokes.
If the Series 500 Keyboard beeps
and LED (2) turns off while
entering key codes at the auxiliary
keyboard, you have exceeded 24
key codes. Repeat steps 1 and 2.
3. At the Series 500 Keyboard, press ENTER.
LED (2) turns off.
4. Program the next function code or exit programming mode by entering 99 on
Series 500 Keyboard numeric keypad or by swiping the Programmer's card. If
using the optional 3-position keyswitch, move switch out of the AUX position.
26 or 36
Comm (RS232)
Main Port 0 (26)
AUX Port 1 (36)
Suffix
1. While in programming mode, at the Series 500 Keyboard numeric keypad,
enter applicable Function Code 26 (Port 0) or 36 (Port 1).
LED (2) flashes.
2. At the auxiliary keyboard, press the desired key or type the desired key
sequence. Note that the maximum number of key codes is limited to 24 - this
is equivalent to approximately 12 key strokes.
If the Series 500 Keyboard beeps
and LED (2) turns off while
entering key codes at the auxiliary
keyboard, you have exceeded 24
key codes. Repeat steps 1 and 2.
3. At the Series 500 Keyboard, press ENTER.
LED (2) turns off.
Program the next function code or exit programming mode by entering 99 on
Series 500 Keyboard numeric keypad or by swiping the Programmer's card. If
using the optional 3-position keyswitch, move switch out of the AUX position.
3 8
1 .
W h i l e i n p r o g r a m m i n g m o d e , a t t h e S e r i e s 5 0 0 K e y b o a r d