NetComm IG6000 User Manual
Page 17
Industrial Modem User Guide
YML3913A
17
#O1
Disconnects if terminal buffer overflows
#O2
Disconnects if line buffer overflows
#O3
Disconnects if either buffer overflows
#PIN=n
Pin Number where n is the pin number
#R0
Remote Control Mode
#V0
Command and S Register verifier off
#V1
n
Command and S Register verifier on
%B0
n
S0=0 setting after AT&F
%B1
S0=2 setting after AT&F
%C0
Compression disabled
%C1
MNP 5 compression enabled
%C2
V.42bis data compression enabled
%C3
n
V.42bis data compression enabled with fallback to MNP 5
%Dn
Set disconnect delay to n seconds (default %D0)
%E0
Disable autoretrain
%E1
n
Enable autoretrain
%E2
Automatic Speed Stepping
%H0
n
Use B setting for initial MNP 10 connection speed
%H1
Initial connection is made at 1200 bps (MNP 10)
%H2
Initial connection is made at 4800 bps (MNP 10)
%H3
Initial connection is made at 9600 bps (MNP 10)
%H9
Use B setting for connection but do not upshift (MNP 10)
%K0
n
CTS operates normally
%K1
CTS off during dial and handshake
%L0
Report current received signal level (dBm)
%Ln
Set transmit level (n=11 to 19; 11dBm to 19dBm)
%M0
n
Mode LEDs indicate connection speed
%M1
Mode LEDs indicate line quality, V.42/MNP errors & flow ctrl
%N0
n
Standard Baud Rates
%N1
Standard to 14400 then 20800, 31200, 41600 and 62400
%N2
Standard to 38400 then 51200
%P0
n
CONNECT message appears before DCD asserted
%P1
CONNECT message appears after DCD asserted
%Q
Report current line quality (EQM) (0=perfect)
%R0
n
&R command determines state of CTS
%R1
CTS always follows RTS (not reset by &F)
%R2
CTS follows DTR when offline (not reset by &F)
%S0
n
DSR is not overridden
%S1
DSR mimics the state of DTR (not reset by &F)
%T0
n
DCD always follows state of carrier
%T1
DCD is always high (not reset by &F)
%U0
n
Standard error correction response codes
%U1
V.42 response codes when V.42 connection established
%U2
V.42 response codes for V.42 connections, MNP 2,4,10 compression
%W0
n
Disable welcome message
%W1
Send message specified by *W to remote modem after connect
\A0
MNP block size = 64
\A1
MNP block size = 128
\A2
MNP block size = 192
\A3
n
MNP block size = 256
\Bn