beautypg.com

Hamilton Sundstrand Company Fuel Metering Valves XVG User Manual

Page 25

background image

Register
Number

XVG/eXVG Parameters
Name

Write

Access

Description Type

3014

IDM_ADCINPRES

RO

Input Pressure counts, range 0-4095

U16

3015

IDM_ADCAI0

RO

Analog Input 0 (demand), range 0-3413

U16

3016

IDM_ADCOUTPRES

RO

Output Pressure counts, range 0-4095

U16

3017

IDM_ADCAI1

RO

Analog Input 1 counts, range 0 – 4095

U16

3018 IDM_ADCDELTAPRES

RO Not

used

U16

3019

IDM_ADCAI2

RO

Analog Input 2 counts, range 0 – 4095

U16

3020

IDM_ADCGASTEMP

RO

Gas Temperature counts

U16

3021

IDM_ADCAI3

RO

Analog Input 3 counts, range 0 – 4095

U16

3022 IDM_ADCSOLTEMP

RO

Solenoid temp counts, not used

U16

3023

IDM_ADCAI4

RO

Analog Input 4 counts, range 0 – 4095

U16

3024

IDM_ADCMOTORCUR

RO

Motor Current counts, range 0 - 4095

U16

3025

IDM_ADCAI5

RO

Analog Input 5 counts, range 0 – 4095

U16

3026

IDM_FFAULTFLGS

RO

Fault Report Variable, not used

U16

3027

IDM_FVERSION

RO

Fault Report Variable, not used

U16

3028

IDM_FRUNTMMINS

RO

Fault Log, Run Time Minutes of fault log

U16

3029

IDM_FRUNTMSECS

RO

Fault Log, Run Time Seconds of fault log

U16

3030

IDM_SETUPERROR

RO

Setup Validation Error Code, 0 = No Errors

U16

3031

IDM_TESTFLAGS

W3

Test Flags (SW debug use only)

U16

3032

IDM_FMODE

RO

Fault Report Variable, not used

U16

3033 IDM_CALFLAGS

W1

Calibration Flags:
Bit0=Set Valve in Calibration State.
The following bits active only in cal state:
Bit1=Enable Feedback Override,
Bit2=Set Solenoid Duty Cycle Out to 50%
Bit3=Read ADC A raw cal voltage into
IDM_ADCACALADC
Bit4=Read ADC B raw cal voltage into
IDM_ADCBCALADC
Bit5=Write parameters to EEPROM Bit6=Reset
IDM_TOTALHRS to 0 if parameter IDM_DATE =
666

U16

3034

IDM_CALAOUT0

W3

Analog Output 0 DAC Value, counts 0-4095

U16

3035

IDM_ADCBCALADC

RO

ADC B 2.5V Ref Calibration counts 0-4095

U16

3036

IDM_AOUT1

W3

Analog Output 1 DAC Value, counts 0-4095

U16

3037

IDM_AOUT2

W3

Analog Output 2 DAC Value, counts 0-4095

U16

3038 IDM_FIRMWAREVER

RO Firmware

Version

U16

3039

IDM_AOUT0

RO

AO0 DAC Value, counts 0-4095

U16

3040 IDM_DIN0

RO

DI0 Value: (reserved for external Run/Stop)
Bit0-Bit3=DI0-DI3 – only used if valve enters
CAL_STATE

U16

3041 IDM_DOUT0

W3

Digital Output 0 Value: (reserved for Fault Output)
Bit0-Bit5=O0-O3, 485TXENA, 485TXENB – only
valid if valve enters CAL_STATE, otherwise for SW
test

U16

25

This manual is related to the following products: