6 flow limiting mode parameters, Flow limiting mode parameters – Hamilton Sundstrand Company Fuel Metering Valves XVG User Manual
Page 23
Register
Number
XVG/eXVG Parameter
Name
Write
Access
Corresponding CdA value
Type
Default
Value
6238 6239
IDM_CDATBLPR7S14
W4
0.618915975 U32
10383687
6240 6241
IDM_CDATBLPR8S0
W4
0.017536998 U32
294222
6242 6243
IDM_CDATBLPR8S1
W4
0.034340978 U32
576146
6244 6245
IDM_CDATBLPR8S2
W4
0.045249999 U32
759169
6246 6247
IDM_CDATBLPR8S3
W4
0.075426996 U32
1265455
6248 6249
IDM_CDATBLPR8S4
W4
0.11294198 U32
1894852
6250 6251
IDM_CDATBLPR8S5
W4
0.154013991 U32
2583926
6252 6253
IDM_CDATBLPR8S6
W4
0.191594005 U32
3214414
6254 6255
IDM_CDATBLPR8S7
W4
0.233344972 U32
3914879
6256 6257
IDM_CDATBLPR8S8
W4
0.258821011 U32
4342296
6258 6259
IDM_CDATBLPR8S9
W4
0.302787006 U32
5079923
6260 6261
IDM_CDATBLPR8S10
W4
0.367821991 U32
6171029
6262 6263
IDM_CDATBLPR8S11
W4
0.415814996 U32
6976218
6264 6265
IDM_CDATBLPR8S12
W4
0.473388016 U32
7942133
6266 6267
IDM_CDATBLPR8S13
W4
0.527272999 U32
8846173
6268 6269
IDM_CDATBLPR8S14
W4
0.584348023 U32
9803733
6270 6271
IDM_CDATBLPR9S0
W4
0.017027974 U32
285682
6272 6273
IDM_CDATBLPR9S1
W4
0.033367991 U32
559822
6274 6275
IDM_CDATBLPR9S2
W4
0.043686986 U32
732946
6276 6267
IDM_CDATBLPR9S3
W4
0.073494017 U32
1233025
6278 6269
IDM_CDATBLPR9S4
W4
0.107271016 U32
1799709
6280 6281
IDM_CDATBLPR9S5
W4
0.150669992 U32
2527823
6282 6283
IDM_CDATBLPR9S6
W4
0.183247983 U32
3074391
6284 6285
IDM_CDATBLPR9S7
W4
0.231404006 U32
3882315
6286 6287
IDM_CDATBLPR9S8
W4
0.25821501 U32
4332129
6288 6289
IDM_CDATBLPR9S9
W4
0.281709015 U32
4726293
6290 6291
IDM_CDATBLPR9S10
W4
0.344421983 U32
5778442
6292 6293
IDM_CDATBLPR9S11
W4
0.391855001 U32
6574236
6294 6295
IDM_CDATBLPR9S12
W4
0.445888996 U32
7480776
6296 6297
IDM_CDATBLPR9S13
W4
0.501824021 U32
8419210
6298 6299
IDM_CDATBLPR9S14
W4
0.544903994 U32
9141972
Table 20: CdA-Pressure Ratio Table Parameters
9.1.6 Flow Limiting Mode Parameters
The following table is used to define the Flow Limiting Mode schedule. The 5-point
Flow Limiting Mode Table defines the minimum and maximum flow limits by
interpolation for a particular backpressure.
Valid Flow Limiting Mode Table Backpressure values are in the range 0.0 - 498.0, 32 bit
floating point format. Valid Flow Limiting Mode Table Minimum Flow values are in the
range 0.0 - 20000.0, 32 bit floating point format. Valid Flow Limiting Mode Table
Maximum Flow values are in the range 0.0 - 20000.0, 32 bit floating point format.
23