beautypg.com

2) detection timer, 3 display – Planet Technology DVR-860 User Manual

Page 34

background image

MENU FUNCTION

-28-

“RE” is to set a reference for detection. The default value is 10, which means the DVR will compare 10 continuous
images at one time according to the sensitivity of LS, SS, TS simultaneously.
The bigger the value is, the higher sensitivity for motion detection. The highest sensitivity is 61.

8) ALARM

Select LOW / HIGH for the alarm polarity. The default alarm value is OFF.

9) PRE / NEXT (DVR-860 Only)

Select “PRE” to go to the previous page; Select “NEXT” to go the next page. Targets set in the AREA.

(2) Detection Timer

Move the cursor to “DETECTION TIMER”, and press ”ENTER”. You will see a similar screen as the following:

DETECTION

DETECTION TIMER

DETECTION SETUP

DATE

START

END

DETECTION TIMER

OFF

00 : 00

-

00 : 00

DAILY

08 : 00

-

18 : 00

SUN

06 : 00

-

23 : 00

MON-FRI

18 : 00

-

23 : 00

OFF

00 : 00

-

00 : 00

OFF

00 : 00

-

00 : 00

OFF

00 : 00

-

00 : 00

Set the date, start time and end time for the detection function. The setting method is similar to “TIMER”. Please refer

to the section “6.2 Timer”.

6.4.3 Display

In this menu list, you can check and change some display settings.
Move the cursor to “DISPLAY”, and press ”ENTER”. You will see a similar screen as the following:

ADVANCE

DISPLAY

CAMERA

TITLE

DISPLAY

ON

DETECTION

DATE

DISPLAY

ON

DISPLAY

HDD

INFO

ON

ALERT LOSS

SCREEN

BLUE

REMOTE

PLAYBACK

INFO

NORMAL

SYSTEM

DWELL DURATION (SEC)

2

NETWORK

DE-INTERLACE

ON

BACKUP

MONITOR

OUT

MAIN

HDD INFO

OSD

SETUP

EVENT LOG

WATERMARK

ON

The submenu items are described below:

1) TITLE

DISPLAY

Select to display the channel title or not (ON / OFF).

2) DATE

DISPLAY

Select to display the date or not (ON / OFF).

3) HDD

INFO

Select to display HDD remaining capacity or not (ON / OFF).

4) LOSS

SCREEN

Set the color for the video loss screen (BLUE / BLACK).

5) PLAYBACK

INFO

Set the position where playback information will be indicated: CENTER or NORMAL (on the button of the left-hand
side of the screen).

6) DWELL DURATION (SEC)

Set the duration time of each channel in second for CALL MONITOR (2 / 4 / 8 / 16).

7) DE-INTERFACE

Select to enable or disable “DE-INTERLACE” function (ON / OFF).