beautypg.com

Samson RFX Keypad 2190 User Manual

Page 19

background image

Keypad Timeout Option:

• Timeout parameter corresponding to the time it takes to validate after

all dispense order data has been entered. If the enter button is not
pressed within the time allocated, the keypad display goes back to the
initial menu, and the input data is erased.

• The keypad timeout is between 0 to 255 seconds (0 no timeout) and

the default for this feature is 10 seconds

Keypad Timeout

10-

Active keys:

Numeric keys,

,

,

Action:

• Press Enter key to move to Hose Inactive Timeout Option


Hose Inactive Timeout Option:

• Essentially, this is the time the user has to top-off the dispense and

completing the automatic batch.

• Timeout parameter corresponding to the time that a RF Meter could

stay inactive after the reset key has been pressed on the meter.

• If the user has not pressed reset on the RF Meter within the timeout

period, the RF Meter will transmit the dispense order quantity to the
keypad and lockout the RF Meter.

• Meter inactive timeout is sent to the RF meter. It’s the meter (ER) that

is responsible of tracking this timer.

• The meter inactive timeout is set for all RF Meters.
• The meter inactive timeout is between 0 to 65534 seconds (0 = no

timeout) and the default value is 10 minutes.

Hose Inactive

600

Active keys:

Numeric keys,

,

,

Action:

• Press Enter key to move to Display Timeout Option

Samson Corporation-Swannanoa, NC 28778 800.311.1047 www.samsoncorporation.com