Hardware monitor logic – SUPER MICRO Computer SUPER X7DB8 User Manual
Page 77
Chapter 4: BIOS
4-19
Hardware Monitor Logic
CPU Temperature Threshold (*See the Note on Page 4-18.)
This option allows the user to set a CPU temperature threshold that will activate
the alarm system when the CPU temperature reaches this pre-set temperature
threshold. The options are 70
o
C, 75
o
C, 80
o
C and 85
o
C.
Highlight this and hit
CPU1 Temperature
CPU1 Second Core
CPU2 Temperature
CPU2 Second Core
System Temperature
Fan1-Fan8 Speeds: If the feature of Auto Fan Control is enabled, the BIOS will
automatically display the status of the fans indicated in this item.
Fan Speed Control Modes
This feature allows the user to decide how the system controls the speeds of the
onboard fans. The CPU temperature and the fan speed are correlative. When
the CPU on-die temperature increases, the fan speed will also increase, and vise
versa. If the option is set to “3-pin fan”, the fan speed is controlled by voltage.
If the option is set to “4-pin”, the fan speed will be controlled by Pulse Width
Modulation (PWM). Select “3-pin” if your chassis came with 3-pin fan headers.
Select “4-pin” if your chassis came with 4-pin fan headers. Select “Workstation”
if your system is used as a Workstation. Select “Server” if your system is used
as a Server. Select “Disable” to disable the fan speed control function to allow
the onboard fans to run at the full speed (12V) at all the time. The Options are:
1. Disable, 2. 3-pin (Server), 3. 3-pin (Workstation), 4. 4-pin (Server) and 5.
4-pin (Workstation).
Voltage Monitoring
The following items will be monitored and displayed:
Vcore A
Vcore B
-12V
P1V5
+3.3V
+12V
5Vsb
5VDD
P_VTT
Vbat