Appendix 3
Interfaces
RS-232 Interface
RS-232 Port
The EasyCoder F4 has, as standard, one serial communication
interface: RS-232.
Default Communication Setup
Baud rate:
9600
Char. length
8 bits
Parity:
None
Stop bits:
1
Protocol:
XON/XOFF
To change the serial interface settings, see Chapter 6, “Setting
Up the Printer.”
Interface Cable
Computer end:
DB-9pin or DB-25pin female connector(PC)
Printer end:
DB-25pin male connector
Host
EasyCoder
F4
Host
Signal DB-9
DB-25 Signal DB-25
DB-25
Signal
1 1
1 1 shield
RXD 2 2 TXD 2 3 RXD
TXD 3 3 RXD 3 2 TXD
CTS 8 4 RTS 4 5 CTS
RTS 7 5 CTS 5 4 RTS
6
DSR
6
20
DTR
GND 5 7
Signal
GND
7 7 GND
16
+
5V
1
16
DSR 6 20 DTR 20 6 DSR
22
RI
22
1
/. The external +5V is limited to 200 mA and is automatically
switched off at overload.