Protocol, Setup parameters, cont – Intermec F4 User Manual
Page 37

Intermec EasyCoder F4 – Installation & Operation IPL Version, Ed. 3
36
Chapter 6 Setting Up the Printer
Setup Parameters, cont.
Serial Communication,
cont.
Protocol
• XON/XOFF (default)
In the XON/XOFF protocol, data fl ow control is achieved by
using XON (DC1) and XOFF (DC3) characters. Message blocks
are not required to be bracketed by the Start of Text (STX) and
End of Text (ETX) characters. However, at power up or after a reset
all characters except ENQ or VT will be ignored until an STX is
detected. The message length in this protocol is unrestricted. That
is, the printer processes information as it is being downloaded and
stops when there is no more information.
XON/XOFF protocol conforms to generally accepted industry
standards. No end-of-message response is sent to the host other
than XOFF. An XON will be sent on power up.
Since DC1 and DC3 are used for data fl ow control, the printer status
characters are different than those of the Standard Protocol. If the
host ignores the printer’s XOFF, the printer will resend an XOFF
after receiving every 15 characters from the host.
Condition Character
Buffer already full
GS
Printhead raised
US
Ribbon fault
US
No label stock
EM
Buffer now full
DC4
Printhead hot
SI
Label at strip pin
FS
Label skipping
DC2
Printing
DC2