0.3 DECALS (continued)
7
WARNING
!
Hazardous voltage. Can cause
severe injury or death.
Only use factory supplied inlet for
incoming power. See Operators/
Instruction manual.
WARNING
!
Hazardous voltage. Can cause
severe injury or death.
Disconnect power before servicing.
Lockout/Tagout machine.
Electrical
power inlet.
VOLTAGE DECAL OPTION
INSIDE STARTER BOX
ON RIGHT SIDE
SCHEMATIC DECAL
54425996 Rev. C (75-160 KW) - 2 REQUIRED
39543764 Rev. 04
39540174 Rev. 05
39541354 Rev 03
Instruction Manual.
WARNING
!
Hazardous voltage. Can cause
severe injury or death.
Only use factory supplied inlet for
incoming power. See Operators/
Instruction manual.
39543764 Rev. 03
Instruction Manual.
Compressor Package Data
COMPRESSOR MODEL...............................
CAPACITY......................................................
RATED OPERATING PRESSURE.................
MAX. DISCHARGE PRESSURE...................
MAX. MODULATE PRESSURE.....................
NOMINAL DRIVE MOTOR............................
NOMINAL FAN MOTOR................................
TOTAL PACKAGE AMPS...............................
VOLTS............................................................
PHASE / HERTZ............................................
CONTROL VOLTAGE.....................................
SERIAL NUMBER..........................................
CONTACTOR AMP. RATING.....................................
ASSEMBLY AMP. RATING........................................
LOCKED ROTOR AMP. RATING OF ASSY. ............
AIR SOLUTIONS GROUP
DAVIDSON, NORTH CAROLINA 28036
WWW.AIR.INGERSOLL-RAND.COM
54425996 Rev.C
m3/MIN
BARG
BARG
BARG
KW
KW
39921804 Rev. B
NOTICE
IEC Starter Overload Setting
1. Full-Voltage Starter (Main or Fan Motor):
Multiply MOTOR nameplate amps by 1.11.
Star-Delta Starter (Main motors only):
Multiply MOTOR nameplate amps by 0.64.
2. Set corresponding overload relay at
this value.
3. Never exceed the following limits:
Full-Voltage Starter: 125% of MOTOR
nameplate amps.
Star-Delta Starter: 72% of MOTOR
nameplate amps.
39557095 Rev.05 (100-200 HP) - 2 REQUIRED
Compressor Package Data
COMPRESSOR MODEL...............................
CAPACITY......................................................
RATED OPERATING PRESSURE.................
MAX. DISCHARGE PRESSURE...................
MAX. MODULATE PRESSURE.....................
NOMINAL DRIVE MOTOR............................
NOMINAL FAN MOTOR................................
TOTAL PACKAGE AMPS...............................
VOLTS............................................................
PHASE / HERTZ............................................
CONTROL VOLTAGE.....................................
SERIAL NUMBER..........................................
CONTACTOR AMP. RATING.....................................
ASSEMBLY AMP. RATING........................................
LOCKED ROTOR AMP. RATING OF ASSY. ............
AIR SOLUTIONS GROUP
DAVIDSON, NORTH CAROLINA 28036
WWW.AIR.INGERSOLL-RAND.COM
39557095 Rev.05
CFM
PSIG
PSIG
PSIG
H.P.
H.P.