7 sensor calibration, 8 alarm history – Ingersoll-Rand 100-200 HP/75-160 KW User Manual
Page 25
3.7 SENSOR CALIBRATION
1 0 0
P S I
-SENSOR CALIBRATION-
Sensor 1AVPT
CALIBRATE
Sensor 3APT
CALIBRATE
STATUS
MAIN MENU
SELECT
Ready To Start
Pressure sensor calibration is done through the
SENSOR CALIBRATION screen. Sensor calibration
can only take place when the machine is stopped.
Calibration needs to be done only after a sensor has
been replaced or the Intellisys controller has been
replaced.
Each of the sensors listed below can be chosen by
using the up and down arrow buttons to highlight it on
the screen.
SENSOR CALIBRATION Items
Sensor 1AVPT
Sensor 3APT
Sensor 4APT
Sensor 5CPT
Sensor 6APT
Select the highlighted sensor by pressing the SELECT
button. Press the CALIBRATE button to start the
automatic calibration procedure, or press the CANCEL
button to not calibrate it and return to the sensor list.
The calibration screen can be exited by pressing either
the STATUS or MAIN MENU buttons. If no buttons are
pressed within 30 seconds, the display will return to
the CURRENT STATUS screen.
0
23
1 0 0
P S I
-ALARM HISTORY-
Alarm History 1
MOTOR OVERLOAD
Alarm History 2
HIGH AIREND DISCH TEMP
3.8 ALARM HISTORY
STATUS
MAIN MENU
SELECT
Ready To Start
Alarm History displays each of the Alarm messages
for the last 15 Alarms experienced by the machine. It
also gives access to displaying the machine operating
conditions that existed at the time of each Alarm. The
first one shown, “Alarm History 1”, was the most
recent Alarm to occur. Note that multiple, consecutive
EMERGENCY STOP Alarms are not recorded as
separate Alarms, only the first one will be shown.
Each of the last 15 Alarm messages can be seen by
moving the Alarm History list up and down using the
arrow buttons. Pressing the SELECT button when one
of the Alarms is highlighted will display the list of
machine values that existed at the time that particular
Alarm occurred.