2 5

2 4

Addendum Required

If a two or five-digit addendum is enabled, then enabling this option
will require an addendum be present before a good read is registered. If
not, then symbols with and without the addendum will be accepted.

G1O for Addendum Required
G1P for Addendum Not Required

Add Separator Space

This option is used with the Two and Five-Digit Addendum options. If
enabled, an ASCII space character is inserted between the data de-
coded from the primary UPC symbol and the addendum symbol.

G1Q to Add Space Separator
G1R to Not Add Space Separator

EAN Settings:

Enable/Disable EAN-13

EAN-13 is a fixed format symbology and there are no variations
allowed. If enabled, EAN-13 symbology will be read, subject to the
reading restrictions specified by this set of options. If disabled, the
data from the symbology will be disregarded.

G2A for EAN-13 Enable
G2B for EAN-13 Disable

Enable/Disable EAN-8

If enabled, EAN-8 symbology will be read, subject to the reading
restrictions specified by this set of options. If disabled, the data from
the symbology will be disregarded.

G2C for EAN-8 Enable
G2D for EAN-8 Disable

Send Induced Country Code Character

The EAN symbology adds an extra digit to the beginning of the data to
create a two-digit country code. If enabled, the added induced charac-
ter is the first character transmitted. If disabled, the induced character
is not transmitted.

G2E for Induced Character Enable
G2F for Induced Character Disable

Send Check Digit

The check digit is mandatory in the EAN symbology. If enabled, the
reader will send the decoded check digit as the last character in the
data stream transmitted. If not, the check character will be suppressed
before transmission.

G2G for Send Check Digit
G2H for Do Not Send Check Digit