Is co nne ct, Al l, Po wer – Goodman Mfg GAS-FIRED WARM AIR FURNACE GKS9 User Manual
Page 39: Be f o re, Se r v ic in g, Th is, Uni t, Ulti p l e, So u rce s, Ma y
39
GKS9 WIRING DIAGRAM
Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
H
IG
H
V
O
LTA
G
E
!
D
IS
CO
NNE
CT
AL
L
PO
WER
BE
F
O
RE
SE
R
V
IC
IN
G
OR
IN
S
T
A
LLI
N
G
TH
IS
UNI
T
.
M
U
LTI
P
L
E
PO
WER
S
O
U
RCE
S
MA
Y
BE
PR
E
S
EN
T
. F
AIL
U
RE
TO
DO
SO
MA
Y
CAU
S
E
PR
O
P
E
R
T
Y
DAM
AG
E
,
P
E
RS
O
NAL
INJ
URY
OR
DE
AT
H
.
R
YL
YELLOW
OR
ORANGE
PU
PURPLE
GN
GREEN
BK
BLACK
BR
BROW N
W H
W HITE
BL
BLUE
GY
GRAY
RD
RED
COLOR
CODES:
LOW
VOLTAGE
(24V)
LOW
VOLTAGE
FIELD
HI
VOLTAGE
(115V)
HI
VOLTAGE
FIELD
NOTES:
1.
SET
HEAT
ANTICIPATOR
ON
ROOM
THERMOSTAT
AT
0.7
AMPS.
2.
MANUFACTURER'S
SPECIFIED
REPLACEMENT
PARTS
MUST
BE
USED
WHEN
SERVICING.
0140F00236
REV.
D
OR
(MED
LOW )
BL
(MED)
RD
(LOW )
G AS
VALVE
C2
C
G
W
INTERNAL
TO
INTEGRATED
CONTROL
JUNCTION
EQUIPMENT
GND
FIELD
GND
DIAGNOSTIC
LED
2
CIRCUIT
CONNE CTOR
HOT
SURFACE
IG NITER
OVERCURRENT
PROT.
DEVICE
IGNITER
TH
(3)
INTEGRATED
CONTROL
MODULE
JUNCTION
BOX
LINE-H
XFMR-H
IN
T
E
GRA
T
ED
CO
NT
R
O
L
M
O
D
U
L
E
IN
T
E
GRA
T
E
D
CO
NT
R
O
L
M
O
D
U
L
E
GND
DISCONNECT
L
N
OVERCURRENT
PROTECTION
DEVICE
RD
BL
B K
4.
IF
HEATING
AND
COOLING
BLOWER
SPEEDS
ARE
NOT
THE
SAME,
DISCARD
JUMPER
BEFORE
CONNECTING
BLOWER
LEADS.
UNUSED
BLOWER
LEADS
MUST
BE
PLACED
ON
"PARK"
TERMINALS
OF
INTEGRATED
CONTROL
OR
TAPED.
3.
IF
ANY
OF
THE
ORIGINAL
WIRE
AS
SUPPLIED
WITH
THE
FURNACE
MUST
BE
REPLACED,
IT
MUST
BE
REPLACED
WITH
WIRING
MATERIAL
HAVING
A
TEMPERATURE
RATING
OF
AT
LEAST
105
TERMINAL
SW ITCH
(PRESS.)
5.
UNIT
MUST
BE
PERMANENTLY
GROUNDED
AND
CONFORM
TO
N.E.C.
AND
LOCAL
CODES.
PK
PINK
115
VAC
HOT
AND
PARK
TERMINALS
LINE-H
FLA ME
SENSOR
BK
PLUG
CONNECTION
FIELD
SPLICE
SWITCH
(TEMP.)
24V
THERMOSTAT
CONNECTIONS
BLOWER
COMPARTMENT
DOOR
SWITCH
(OPEN
WHEN
DOOR
OPEN)
DOOR
SWITCH
BK
JUNCTION
BOX
1
HEAT-H
N
O
COOL-H
MANUAL
RESET
AUXILIARY
LIMIT
IN
UPFLOW
BLOW ER
DECK
C
FS
HE
AT
-H
CO
OL
IGNITER
HOT
SURFACE
IND
IGN
BLWR
CIRCULATOR
BLWR
ID
FLAME
SENSOR
115
VAC
TRANSFORMER
40
VA
24
VAC
GND
RO1
(5)
RO2
(11)
HLO
(1)
HLI
(7)
MVC
(9)
GND
(8)
TR
(6)
OR
WH
WH
BL
YL
OR
RD
GR
BR
PK
1
1
5
V
A
C
N
E
UT
RA
L
BK
BK
2
4
V
TH
ER
M
O
ST
A
T
C
O
NN
EC
T
IO
N
S
MICRO
TO
C
G
Y
W
R
2
WH
XF
M
R
-H
TE
R
M
IN
A
L
S
1
2
3
12
11
10
9
8
7
6
5
4
°C.
USE
COPPER
CONDUCTORS
ONLY.
24
VAC
HUMIDIFIER
24
VAC
HUMIDIFIER
HUMIDIFIER
PSO
(4)
MV(12)
PS
(10)
C
NO
ID
BLOWER
PRESSURE
SWITCH
0
C
6
5
4
3
2
1
OFF
=
CONTROL
FAILURE
STEADY
ON
=
NORMAL
OPERATION
1
FLASH
=
2
FLASHES
=
PRESSURE
SW ITCH
STUCK
CLOSED
3
FLASHES
=
PRESSURE
SW ITCH
STUCK
OPEN
4
FLASHES
=
OPEN
HIGH
LIMIT
5
FLASHES
=
FLAME
SENSE
WITHOUT
GAS
VALVE
6
FLASHES
=
CONTINUOUS/RAPID
FLASHES
=
REVERSED
115
VAC
POLARITY
FUSE
MI
GY
M1
GAS
VALVE
C2
TO
115VAC/
1 Ø
/60
HZ
POW ER
SUPPLY
W ITH
Y
L
IN
E
NE
UT
RA
L
S
NO
C
C
N
O
OPTIONAL
FRONT
COVER
PRESSURE
SWITCH