beautypg.com

Is co nne ct, Al l, Po wer – Goodman Mfg GAS-FIRED WARM AIR FURNACE GKS9 User Manual

Page 39: Be f o re, Se r v ic in g, Th is, Uni t, Ulti p l e, So u rce s, Ma y

background image

39

GKS9 WIRING DIAGRAM

Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.

H

IG

H

V

O

LTA

G

E

!

D

IS

CO

NNE

CT

AL

L

PO

WER

BE

F

O

RE

SE

R

V

IC

IN

G

OR

IN

S

T

A

LLI

N

G

TH

IS

UNI

T

.

M

U

LTI

P

L

E

PO

WER

S

O

U

RCE

S

MA

Y

BE

PR

E

S

EN

T

. F

AIL

U

RE

TO

DO

SO

MA

Y

CAU

S

E

PR

O

P

E

R

T

Y

DAM

AG

E

,

P

E

RS

O

NAL

INJ

URY

OR

DE

AT

H

.

R

YL

YELLOW

OR

ORANGE

PU

PURPLE

GN

GREEN

BK

BLACK

BR

BROW N

W H

W HITE

BL

BLUE

GY

GRAY

RD

RED

COLOR

CODES:

LOW

VOLTAGE

(24V)

LOW

VOLTAGE

FIELD

HI

VOLTAGE

(115V)

HI

VOLTAGE

FIELD

NOTES:

1.

SET

HEAT

ANTICIPATOR

ON

ROOM

THERMOSTAT

AT

0.7

AMPS.

2.

MANUFACTURER'S

SPECIFIED

REPLACEMENT

PARTS

MUST

BE

USED

WHEN

SERVICING.

0140F00236

REV.

D

OR

(MED

LOW )

BL

(MED)

RD

(LOW )

G AS

VALVE

C2

C

G

W

INTERNAL

TO

INTEGRATED

CONTROL

JUNCTION

EQUIPMENT

GND

FIELD

GND

DIAGNOSTIC
LED

2

CIRCUIT

CONNE CTOR

HOT
SURFACE
IG NITER

OVERCURRENT

PROT.

DEVICE

IGNITER

TH

(3)

INTEGRATED
CONTROL

MODULE

JUNCTION

BOX

LINE-H

XFMR-H

IN

T

E

GRA

T

ED
CO

NT
R

O

L

M

O

D

U

L

E

IN

T

E

GRA

T

E

D

CO

NT
R

O

L

M
O

D

U

L

E

GND

DISCONNECT

L

N

OVERCURRENT

PROTECTION

DEVICE

RD

BL

B K

4.

IF

HEATING

AND

COOLING

BLOWER

SPEEDS

ARE

NOT

THE

SAME,

DISCARD

JUMPER

BEFORE

CONNECTING

BLOWER

LEADS.

UNUSED

BLOWER

LEADS

MUST

BE

PLACED

ON

"PARK"

TERMINALS

OF

INTEGRATED

CONTROL

OR

TAPED.

3.

IF

ANY

OF

THE

ORIGINAL

WIRE

AS

SUPPLIED

WITH

THE

FURNACE

MUST

BE

REPLACED,

IT

MUST

BE

REPLACED

WITH

WIRING

MATERIAL

HAVING

A

TEMPERATURE

RATING

OF

AT

LEAST

105

TERMINAL

SW ITCH

(PRESS.)

5.

UNIT

MUST

BE

PERMANENTLY

GROUNDED

AND

CONFORM

TO

N.E.C.

AND

LOCAL

CODES.

PK

PINK

115

VAC

HOT

AND

PARK

TERMINALS

LINE-H

FLA ME
SENSOR

BK

PLUG

CONNECTION

FIELD

SPLICE

SWITCH

(TEMP.)

24V

THERMOSTAT

CONNECTIONS

BLOWER
COMPARTMENT
DOOR

SWITCH

(OPEN

WHEN

DOOR

OPEN)

DOOR
SWITCH

BK

JUNCTION

BOX

1

HEAT-H

N
O

COOL-H

MANUAL

RESET

AUXILIARY

LIMIT

IN

UPFLOW

BLOW ER

DECK

C

FS

HE

AT

-H

CO

OL

IGNITER

HOT

SURFACE

IND

IGN

BLWR

CIRCULATOR

BLWR

ID

FLAME

SENSOR

115

VAC

TRANSFORMER

40

VA

24

VAC

GND

RO1

(5)

RO2

(11)

HLO

(1)

HLI

(7)

MVC

(9)

GND

(8)

TR

(6)

OR

WH

WH

BL

YL

OR

RD

GR

BR

PK

1

1

5

V

A

C
N

E

UT
RA
L

BK

BK

2

4

V

TH

ER
M

O

ST
A

T

C

O

NN

EC
T

IO

N

S

MICRO

TO

C

G

Y

W

R

2

WH

XF
M

R

-H

TE
R

M

IN

A

L

S

1

2

3

12

11

10

9

8

7

6

5

4

°C.

USE

COPPER

CONDUCTORS

ONLY.

24

VAC

HUMIDIFIER

24

VAC

HUMIDIFIER

HUMIDIFIER

PSO

(4)

MV(12)

PS

(10)

C

NO

ID

BLOWER

PRESSURE

SWITCH

0

C

6

5

4

3

2

1

OFF

=

CONTROL

FAILURE

STEADY

ON

=

NORMAL

OPERATION

1

FLASH

=

2

FLASHES

=

PRESSURE

SW ITCH

STUCK

CLOSED

3

FLASHES

=

PRESSURE

SW ITCH

STUCK

OPEN

4

FLASHES

=

OPEN

HIGH

LIMIT

5

FLASHES

=

FLAME

SENSE

WITHOUT

GAS

VALVE

6

FLASHES

=

CONTINUOUS/RAPID

FLASHES

=

REVERSED

115

VAC

POLARITY

FUSE

MI

GY

M1

GAS

VALVE

C2

TO

115VAC/

1 Ø

/60

HZ

POW ER

SUPPLY

W ITH

Y

L

IN

E

NE

UT
RA
L

S

NO

C

C

N
O

OPTIONAL

FRONT

COVER

PRESSURE

SWITCH