Furuno, Power supply, Environmental conditions – Furuno BB FAR28x7 User Manual
Page 25: Sp - 3
FURUNO
FAR-21x7(-BB)/28x7 SERIES
SP - 3
E3519S01L-M
PM-51 (S-band)
1. Frequency range
3020 to 3080 MHz
2. Input power
Min. -5 dBm, Max. +15 dBm
3. Power output (2
nd
pulse max output)
-15 dBm
4. Power output (2
nd
pulse min output)
-35 dBm
5. Steps levels (1
st
pulse to 2
nd
pulse)
9.0 to 11.0 dB
6. POWER SUPPLY
1. Display unit
24 VDC or 115/230 VAC, 1ø, 50/60 Hz
FAR-21x7: 24 VDC, 2.3 A; 100-230 VAC, 0.7A (100 V)
FAR-28x7: 24 VDC, 3.2 A; 100-230 VAC, 0.9 A (100 V)
440 VAC, 1 ø, 50/60 Hz with optional transformer RU-1803
2. Processor unit
FAR-2117/2817/2117-BB:
24VDC: 7.6A
1
/8.5A
2
, 100-115 VAC: 2.6A
1
/3.0A
2
,
220-230 VAC: 1.6A
1
/1.7A
2
FAR-2127/2827/2127-BB:
24 VDC: 8.8A
1
/9.7A
2
, 100-115 VAC: 3.0A
1
/3.4A
2
,
220-230 VAC: 1.8A
1
/1.9A
2
1:
24 rpm,
2:
42 rpm
FAR-2827W:
3.2A (100-115 VAC), 1.6A (220-230 VAC)
FAR-2157/2157-BB/2167DS/2167DS-BB/2137S/2137S-BB/2837S/
2837SW:
3.0A (100-115 VAC), 1.5A (220-230 VAC)
3. Antenna unit
X-band: 24 VDC, 4A, 200/220 VAC, 2A, 3
ø
, 50/60 Hz
S-band: 200/220/380/440 VAC
115/230 VAC, 1ø, 50 or 60 Hz
Antenna voltage input (100 kt)
Model
200 VAC,
ø3, 50 Hz,
220 VAC,
ø3, 60 Hz
380 VAC,
ø3, 50 Hz,
440 VAC,
ø3, 60 Hz
220 VAC,
ø3, 50 Hz,
(HSC)
220 VAC,
ø3, 60 Hz,
(HSC)
440 VAC,
ø3, 60 Hz
(HSC)
FAR-2137S(BB)
3.0 A
1.5 A
3.5 A
3.5 A
1.7 A
FAR-2167DS(BB) 3.0 A
1.5 A
-
-
-
FAR-2837S
3.0 A
1.5 A
3.5 A
3.5 A
1.7 A
FAR-2837SW
3.0 A
1.5 A
-
-
-
FAR-2137SW
3.0 A
1.5 A
-
-
-
4.
Console
115/230 VAC, 1ø, 50/60 Hz, 440 VAC, 1ø, 50/60 Hz with optional
transformer RU-1803
7. ENVIRONMENTAL CONDITIONS
1. Ambient temperature (Complies with IEC 60945)
Indoor units
-15°C to +55°C
Antenna unit
-25°C to +55°C (storage +70°C)
2. Relative humidity
95% at 40°C
3. Waterproofing
Antenna unit: IPX6 (IEC 60529)
Indoor units: IPX0 (IEC 60529)
4. EMC
Full compliance with IEC 60945 Ed. 4