beautypg.com

Furuno, Power supply, Environmental conditions – Furuno BB FAR28x7 User Manual

Page 25: Sp - 3

background image

FURUNO

FAR-21x7(-BB)/28x7 SERIES

SP - 3

E3519S01L-M

PM-51 (S-band)

1. Frequency range

3020 to 3080 MHz

2. Input power

Min. -5 dBm, Max. +15 dBm

3. Power output (2

nd

pulse max output)

-15 dBm

4. Power output (2

nd

pulse min output)

-35 dBm

5. Steps levels (1

st

pulse to 2

nd

pulse)

9.0 to 11.0 dB

6. POWER SUPPLY

1. Display unit

24 VDC or 115/230 VAC, 1ø, 50/60 Hz
FAR-21x7: 24 VDC, 2.3 A; 100-230 VAC, 0.7A (100 V)
FAR-28x7: 24 VDC, 3.2 A; 100-230 VAC, 0.9 A (100 V)
440 VAC, 1 ø, 50/60 Hz with optional transformer RU-1803

2. Processor unit

FAR-2117/2817/2117-BB:
24VDC: 7.6A

1

/8.5A

2

, 100-115 VAC: 2.6A

1

/3.0A

2

,

220-230 VAC: 1.6A

1

/1.7A

2

FAR-2127/2827/2127-BB:
24 VDC: 8.8A

1

/9.7A

2

, 100-115 VAC: 3.0A

1

/3.4A

2

,

220-230 VAC: 1.8A

1

/1.9A

2

1:

24 rpm,

2:

42 rpm

FAR-2827W:
3.2A (100-115 VAC), 1.6A (220-230 VAC)

FAR-2157/2157-BB/2167DS/2167DS-BB/2137S/2137S-BB/2837S/

2837SW:
3.0A (100-115 VAC), 1.5A (220-230 VAC)

3. Antenna unit

X-band: 24 VDC, 4A, 200/220 VAC, 2A, 3

ø

, 50/60 Hz

S-band: 200/220/380/440 VAC

115/230 VAC, 1ø, 50 or 60 Hz

Antenna voltage input (100 kt)

Model

200 VAC,
ø3, 50 Hz,
220 VAC,
ø3, 60 Hz

380 VAC,
ø3, 50 Hz,
440 VAC,
ø3, 60 Hz

220 VAC,
ø3, 50 Hz,
(HSC)

220 VAC,
ø3, 60 Hz,
(HSC)

440 VAC,
ø3, 60 Hz
(HSC)

FAR-2137S(BB)

3.0 A

1.5 A

3.5 A

3.5 A

1.7 A

FAR-2167DS(BB) 3.0 A

1.5 A

-

-

-

FAR-2837S

3.0 A

1.5 A

3.5 A

3.5 A

1.7 A

FAR-2837SW

3.0 A

1.5 A

-

-

-

FAR-2137SW

3.0 A

1.5 A

-

-

-

4.

Console

115/230 VAC, 1ø, 50/60 Hz, 440 VAC, 1ø, 50/60 Hz with optional
transformer RU-1803

7. ENVIRONMENTAL CONDITIONS

1. Ambient temperature (Complies with IEC 60945)
Indoor units

-15°C to +55°C

Antenna unit

-25°C to +55°C (storage +70°C)

2. Relative humidity

95% at 40°C

3. Waterproofing

Antenna unit: IPX6 (IEC 60529)
Indoor units: IPX0 (IEC 60529)

4. EMC

Full compliance with IEC 60945 Ed. 4
(to 2 GHz cabinet radiation)