beautypg.com

2 life expectancy of major parts, 3 replacing the fuse, Warning – Furuno BB FAR28x7 User Manual

Page 237

background image

6. MAINTENANCE, TROUBLESHOOTING

6-3

WARNING

Use the proper fuse.

Use of a wrong fuse can result in damage
to the equipment or cause fire.

6.2

Life Expectancy of Major Parts

Parts Type

Life

expectancy

Remarks

Antenna motor

D8G-516 (24 rpm, X-band)
D8G-571 (42 rpm, X-band)
GOB-8222 (18/22 rpm, X-band, 200 VAC)
RM-6585 (18/22 rpm, X-band, 24 VDC)
RM-7398 (21/26 rpm, S-band)
RM-7435 (21/26 rpm, S-band)
RM-9519 (45 rpm, S-band)
RM-9520 (45 rpm, S-band)
RM-9521 (45 rpm, S-band)

Gears more than
10,000 h

Wind load
100 kt

Magnetron

9M31(F) (X-band, 50 kW)
MAF-1425B (X-band, 12 kW)
MG4010 (X-band, 12 kW)
MG5240 F (S-band, 60 kW)
MG5436 (X-band, 25 kW)
MG5223F (S-band, 30 kW)

2,000 - 3,000 h

Backlight Unit for
Display Unit
MU-201CR

201LHS2F 45,000

h(25°C)

30,000 h(50°C)

Cold Cathode
Fluorescent Lamp
for Display Unit
MU-231CR

FLCL-23 50,000

h(25°C)

35,000 h(50°C)

6.3 Replacing

the

Fuse

The fuse at the rear of the processor unit
in the display unit protects the equipment
from overcurrent (overvoltage in case of
AC set) and equipment fault. If you cannot
turn on the power, first check the fuse.
Find the cause of the trouble before
replacing the fuse. Be sure to use the
proper fuse. Use of a wrong fuse can
seriously damage the equipment and void
the warranty.

Ship’s mains and fuse to use

Unit

Power

Fuse to use

24 VDC

20A

100-115 VAC

10A

Processor Unit

220-230 VAC

5A

100-115 VAC

5A

Power Supply Unit PSU-006

220-230 VAC

3A

100-230 VAC

2A

Display Unit MU-201CR

24 VDC

5A

100-230 VAC

2A

Display Unit MU-231CR

24 VDC

6A