2 life expectancy of major parts, 3 replacing the fuse, Warning – Furuno BB FAR28x7 User Manual
Page 237
6. MAINTENANCE, TROUBLESHOOTING
6-3
WARNING
Use the proper fuse.
Use of a wrong fuse can result in damage
to the equipment or cause fire.
6.2
Life Expectancy of Major Parts
Parts Type
Life
expectancy
Remarks
Antenna motor
D8G-516 (24 rpm, X-band)
D8G-571 (42 rpm, X-band)
GOB-8222 (18/22 rpm, X-band, 200 VAC)
RM-6585 (18/22 rpm, X-band, 24 VDC)
RM-7398 (21/26 rpm, S-band)
RM-7435 (21/26 rpm, S-band)
RM-9519 (45 rpm, S-band)
RM-9520 (45 rpm, S-band)
RM-9521 (45 rpm, S-band)
Gears more than
10,000 h
Wind load
100 kt
Magnetron
9M31(F) (X-band, 50 kW)
MAF-1425B (X-band, 12 kW)
MG4010 (X-band, 12 kW)
MG5240 F (S-band, 60 kW)
MG5436 (X-band, 25 kW)
MG5223F (S-band, 30 kW)
2,000 - 3,000 h
Backlight Unit for
Display Unit
MU-201CR
201LHS2F 45,000
h(25°C)
30,000 h(50°C)
Cold Cathode
Fluorescent Lamp
for Display Unit
MU-231CR
FLCL-23 50,000
h(25°C)
35,000 h(50°C)
6.3 Replacing
the
Fuse
The fuse at the rear of the processor unit
in the display unit protects the equipment
from overcurrent (overvoltage in case of
AC set) and equipment fault. If you cannot
turn on the power, first check the fuse.
Find the cause of the trouble before
replacing the fuse. Be sure to use the
proper fuse. Use of a wrong fuse can
seriously damage the equipment and void
the warranty.
Ship’s mains and fuse to use
Unit
Power
Fuse to use
24 VDC
20A
100-115 VAC
10A
Processor Unit
220-230 VAC
5A
100-115 VAC
5A
Power Supply Unit PSU-006
220-230 VAC
3A
100-230 VAC
2A
Display Unit MU-201CR
24 VDC
5A
100-230 VAC
2A
Display Unit MU-231CR
24 VDC
6A