1. RADAR OPERATION

1-91

5. Roll the wheel to choose 2 BKGD COLOR and then push the wheel or the

left button.

6. Roll the wheel to choose background color and surrounding color

combination desired and then push the wheel or the left button.

7. Set brilliance-related items referring to paragraph 1.38.
8. Push the right button to close the BRILL menu.

1.50 Reference Point for CPA/TCPA

The common reference point for CPA/TCPA can be chosen from antenna
position or conning position as shown below. Echo sweep center and sector
blanking symbol are always referenced to antenna position regardless of
reference point chosen. For conning position, which is entered at installation,
EBL and VRM are referenced to conning position.

1. Roll the trackball to choose the Reference Point Box at the top of the screen.

REF POINT
ANT POSN

Reference point box

2. Push the right button to choose ANT POSN or CONN POSN as appropriate.