3. CHANGING

POWER

SPECIFICATIONS

This unit is set at factory to operate from 220-230 VAC ship's mains. For connection to a 100
VAC, 110-115 VAC, 200 VAC or 24 VDC ship's mains, modify the connections in the distribution
box as shown below.

Note: Tick the appropriate box on the inside of the FE-702 distribution box cover to denote the
power use.

200-230 VAC (50/60 Hz)
100-115 VAC (50/60 Hz)

24 VDC

Label inside the distribution box FE-702

100 VAC, 110-115 VAC, 200 VAC Ship's Mains

1. Connect the power cable to #1 & #3 on TB5 in the distribution box.

2. Modify the wiring at TB7 according to ship's mains as shown in the table below.

Ship's mains

TB7 #1

TB7 #2

TB7 #3

TB7 #4

TB7 #5

220-230 VAC
(Default)

Orange Red Black Brown White

200 VAC

Red

Orange

Black

Brown

White

110-115 VAC

Black

Red

Orange

Brown

White

100VAC Brown

Red

Black

Orange

White