7. Make sure the extension cord is properly
wired and in good electrical condition.
Always replace a damaged extension
cord or have it repaired by a qualified
electrician before using it.
8. Protect the extension cords from sharp
objects, excessive heat, and damp or
wet areas.
RECOMMENDED MINIMUM WIRE GAUGE
FOR EXTENSION CORDS*
(120/240 VOLT)
NAMEPLATE
AMPERES
(at full load)
EXTENSION CORD
LENGTH
25’ 50’ 75’ 100’ 150’
0 – 2.0
18
18
18
18
16
2.1 – 3.4
18
18
18
16
14
3.5 – 5.0
18
18
16
14
12
5.1 – 7.0
18
16
14
12
12
7.1 – 12.0
18
14
12
10
-
12.1 – 16.0
14
12
10
-
-
16.1 – 20.0
12
10
-
-
-
TABLE A
* Based on limiting the line volt‑
age drop to five volts at 150% of
the rated amperes.
Symbology
Double Insulated
Canadian Standards Association
Underwriters Laboratories, Inc.
V~
Volts Alternating Current
A
Amperes
n0 xxxx/min.
No Load Revolutions per Minute
(RPM)
SPM
Strokes Per Minute
SPECIFICATIONS
Electrical Input
120V~ / 60Hz / 5.5A
Laser Power
2 “AAA” Batteries
(sold separately)
Speed Rating
500 to 3,000 SPM
6 settings
Stroke Length
11/16
˝ with 4 orbital settings
Blade Type
Universal - Clamp Type Holder
Saw Blades
(2x) 4
˝ x 10 TPI,
(1x) 3-1/4
˝ x 25 TPI
Bevel Adjustment
0-45° Left / 0-45° Right
Maximum Cutting Depth 2-1/2˝ @ 90° (Wood) / 1/4˝ @ 90°
(Steel)