Figure 8.
Intermittent Pilot Ignition (IPI) Wiring Diagram
If your fireplace look like Figure 7 find the leads on the back of switch marked “For use with remote or wall switch only”.
Take the leads and plus them into wire leads on remote receiver box (see Figure 8).
ON/OFF
SLIDE
SWITCH
BLACK
RED
BATTERY PACK
PIGGYBACK
ON/OFF SWITCH
GR
N
OR
G
BR
O
W
N
BR
O
W
N
ORANGE
WHITE
TRANSFORMER
3 VAC
PLUG IN
GROUND TO
FIREPLACE CHASSIS
INTERMITTENT
PILOT
IGNITOR
IGNITION
MODULE
3 VAC
VALVE
F or u se with
remote o r
wall switch o nly
1 2 3
NEUT
RAL
HO
T
5
4
3
2
1
5
4
3
2
1
TRAN
S
REM
/A
UX
FAN
I
S
LE
A
R
N
REMOTE
RECEIVER
WIRE
TERMINAL